3-74
3-4 Cable and Connector Specifications
OMNUC G5-Series AC Servo Drives Users Manual (Built-in MECHATROLINK-II communications type)
3
Specifications
XW2B-20G5
Note The pitch of terminals is 8.5 mm.
Precautions for Correct Use
When using crimp terminals, use crimp terminals with the following dimensions.
When connecting wires and crimp terminals to a terminal block, tighten them with a tightening
torque of 0.59 N•m.
2
1
1
2
20
19
19
20
(45.3)
43.5
29.5
7
8.5
7.3
3.5
7
3.5
112.5
15.5
45
2-
φ
3.5
20.5
Dimensions
Flat cable connector
(MIL type plug)
Terminal block
φ
3.7 mm
3.7 mm
6.8mm max.
6.8mm max.
Round terminal
Fork terminal
Applicable crimp terminals
Applicable wires
Round terminals
1.25
3
AWG22
16 (0.30 to 1.25 mm
2
)
2
3.5
AWG16
14 (1.25 to 2.0 mm
2
)
Fork terminals
1.25Y
3
AWG22
16 (0.30 to 1.25 mm
2
)
2
3.5
AWG16
14 (1.25 to 2.0 mm
2
)