3-8
3-1 Servo Drive Specifications
OMNUC G5-Series AC Servo Drives Users Manual (Built-in MECHATROLINK-II communications type)
3
Specifications
Main Circuit and Motor Connections
When wiring the main circuit, use proper wire sizes, grounding systems, and noise resistance.
R88D-KNA5L-ML2/-KN01L-ML2/-KN02L-ML2/-KN04L-ML2/-KN01H-ML2/
-KN02H-ML2/-KN04H-ML2/-KN08H-ML2/-KN10H-ML2/-KN15H-ML2
Main Circuit Connector Specifications (CNA)
Motor Connector Specifications (CNB)
Symbol
Name
Function
L1
Main circuit power
supply input
R88D-KNxL-ML2
(50 to 400 W) : Single-phase 100 to 115 VAC (85 to 127 V) 50/60 Hz
(200 to 400 W) : 3-phase: 200 to 240 VAC (170 to 264 V) 50/60 Hz
R88D-KNxH-ML2
(50 W to 1.5 kW) : Single-phase: 200 to 240 VAC (170 to 264 V) 50/
60 Hz
(100 W to 1.5 kW) : 3-phase: 200 to 240 VAC (170 to 264 V) 50/60 Hz
Note. Single-phase should connect to L1 or L3.
L2
L3
L1C
Control circuit power
supply input
R88D-KNxL-ML2 : Single-phase 100 to 115 VAC (85 to 127 V) 50/60
Hz
R88D-KNxH-ML2 : Single-phase 200 to 240 VAC (170 to 264 V) 50/
60 Hz
L2C
Symbol
Name
Function
B1 External
Regeneration
Resistor connection
terminals
Normally B2 and B3 are short-circuited.
If there is high regenerative energy, remove the short-circuit bar
between B2 and B3 and connect an External Regeneration Resistor
between B1 and B2. (R88D-KN08H-ML2/ KN10H-ML2/ KN15H-ML2)
B2
B3
U
Motor connection
terminals
Phase U
These are the output terminals to the Servomotor.
Be sure to wire them correctly.
V
Phase V
W
Phase W