9-5
9-2 Preparing for Operation
OMNUC G5-Series AC Servo Drives Users Manual (Built-in MECHATROLINK-II communications type)
9
Operation
Checking the Displays
7-Segment LED Indicator
The 7-segment LED indicator is on the front panel.
When the power is turned on, it shows the node address that is set by the rotary switches. Then the
indication changes in accordance with the setting on the Default Display (Pn700).
If any alarming error occurs, it indicates the error number (Alarm No.xx) as the alarm code. If any
warning situation occurs, it indicates the warning number as the warning code.
*1. When the Safety input error (Alarm No.33.0) occurs, the alarm code is not shown. Instead, "St" flashes.
Warning occurs
Warning resolved
Control power on
Main power is ON
and the network
communication
is established.
Main power is OFF and the network
communication is not established.
Servo ON
Servo OFF
[
−
−
]
Fully unlit
Fully lit (for approx. 0.6 s)
[nA] (Node Address) (for approx. 0.6 s)
Rotary switch setting (This example is the case
when the MSD is set to 0 and the LSD is to 3.)
(Power ON Address Display Duration Setting
at power ON (Pn701).)
[
−
−
]
+
Right dot lights
[00]
+
Right dot lights
Alarm occurs
Alarm cleared
Warning code
(for 2 s)
Normal indication
(for approx 4 s)
<Alarm display>
*1
<Normal display (When the Default Display (Pn700) is set to 0.)>
<Node address display>
The alarm code in a decimal number flashes.
(E.g. overload)
<Warning display>
The warning code hex and the normal
indication show alternatively. (E.g. overload)