8-54
8-7 Special Parameters
OMNUC G5-Series AC Servo Drives Users Manual (Built-in MECHATROLINK-II communications type)
8
Parameters Details
Set the allowable time required until the motor stops by an emergency stop due to an alarm.
When he time exceeds the set value, the operation forcibly turns to an alarming state.
When the parameter is set to 0, the protection by allowable time does not function.
Refer to the Emergency Stop Operation at Alarms in "11-3 Alarms (P.11-6)".
If the motor speed exceeds the set value during an emergency stop due to an alarm, the
Overspeed 2 (Alarm No.26.1) occurs.
The overspeed detection level setting is 1.2 times the maximum motor rotation speed if this
parameter is set to 0.
This parameter should normally be set to 0. The setting should be changed only when it is
necessary to lower the overspeed detection level.
Refer to "Emergency Stop Operation at Alarms" (P.11-13) in "11-3 Alarms (P.11-6)".
Set initialization time after power supply ON to the standard 1.5 seconds plus some.
Refer to the Control Output Sequence in "3-1 Servo Drive Specifications (P.3-1)" for the details at power
on.
Pn614
Alarm Detection Allowable Time Setting
Setting
range
0 to 1000
Unit
ms
Default
setting
200
Data
attribute
B
All
Pn615
Overspeed Detection Level Setting at
Emergency
Stop
Setting
range
0 to 20000
Unit
r/min
Default
setting
0
Data
attribute
A
All
Pn616
Unused
Setting
range
Unit
Default
setting
Data
attribute
All
Pn617
Unused
Setting
range
Unit
Default
setting
Data
attribute
All
Pn618
Power Supply ON Initialization Time
Setting
range
0 to 100
Unit
0.1 s
Default
setting
0
Data
attribute
R
All
Pn619
Unused
Setting
range
Unit
Default
setting
Data
attribute
All
Pn620
Unused
Setting
range
Unit
Default
setting
Data
attribute
All
Pn621
Unused
Setting
range
Unit
Default
setting
Data
attribute
All