manualshive.com logo in svg
background image

IDEMIA DOCUMENT 

– REPRODUCTION AND DISCLOSURE PROHIBITED

MorphoAccess

®

SIGMA 

Extreme Series

Quick User Guide

2017_2000024419 

– V4

All descriptions, illustrations, and specifications in this brochure should be 
considered approximate and may relate to optional equipment or feature

Содержание MorphoAccess SIGMA Extreme Series

Страница 1: ...CLOSURE PROHIBITED MorphoAccess SIGMA Extreme Series Quick User Guide 2017_2000024419 V4 All descriptions illustrations and specifications in this brochure should be considered approximate and may rel...

Страница 2: ...LOSURE PROHIBITED Table of Contents IDEMIA 2017_2000024419 V4 2 Color Step Content One Overview Two Wiring Three Communication Four SDAC Single Door Access Control Five Administration Six Software Sev...

Страница 3: ...t Overview IDEMIA 2017_2000024419 V4 3 for configuration with a USB mass storage key Power consumption shall not exceed 200mA Standard SIGMA Fake Finger Detection SIGMA FFD 5 WVGA touchscreen LCD Embe...

Страница 4: ...ccess SIGMA Extreme Checklist IDEMIA 2017_2000024419 V4 4 Step one overview QTY ITEM 1 MorphoAccess SIGMA Extreme terminal 1 Wall Mounting Plate 1 Documentation package Electronic documentation is pro...

Страница 5: ...s granted i e if the individual s User ID is listed in the Controller authorized user List Control of the latch is made through a dry contact An Alarm 3rd party product The MorphoAccess terminal sends...

Страница 6: ...2000024419 V4 6 On Access Request the terminal checks user s access rights using a biometric check If the result of the check is successful user recognized a message is sent to the Central Access Cont...

Страница 7: ...ntication triggers are enabled Triggering events are selected by the remote application Biometric check if enabled The user s captured fingerprint is matched against all fingerprints in the terminal d...

Страница 8: ...e or combustible gases or materials The terminal is not designed to be intrinsically safe The terminal should be installed in controlled lighting conditions Avoid biometric sensor exposure to a blinki...

Страница 9: ...pply RJ 45 Ethernet PoE 1 ETH TX Orange White 2 ETH TX Orange 3 ETH RX Green White 4 ETH VPORT Blue 5 ETH VPORT Blue White 6 ETH RX Green 7 ETH VPORT Brown White 8 ETH VPORT Brown Shell ETH GND Drain...

Страница 10: ...p two wiring 25 Power 12V Red 26 Power GND Black PoE Injector Specs Output Voltage 48VDC Output Current 0 32A Power 15 36W A battery backup or uninterrupted power supply UPS with built in surge protec...

Страница 11: ...rom the Com Port RS 232 to RS 485 converter RS 485 to 1200m 4000ft For RS 485 installations the cable should be run in a daisy chain configuration i e converter position 1 position 2 position 3 etc Us...

Страница 12: ...t be dedicated to this installation and not used for any other purpose For RS 422 installations the cable should be run in a point to point configuration i e PC converter terminal Use CAT 5 UTP or bet...

Страница 13: ...2 11b and 802 11g standards WEP Open WPA and WPA2 are supported Use a category 5 shielding cable 120 Ohms or better It is strongly recommended to insert a repeater unit every 90m Static mode is enable...

Страница 14: ...is required for Data 0 Data 1 and WGND Use 18 22 AWG cable in a homerun configuration from each unit to the Access Control Panel ACP Connect WIEGAND_OUT0 Green wire Pin 14 to ACP Data 0 Connect WIEGAN...

Страница 15: ...On installation the system administrator will be prompted to select either a pre existing Wiegand frame format or create a custom format and upload it to the unit before the first use Data Clock The...

Страница 16: ...1 RELAY_NO Yellow White 22 RELAY_COM Grey White If door contact is not used GPI1 15 and GPO1 16 shall be connected together Power supply Single Door Access Control SDAC wiring sample with Push Button...

Страница 17: ...mage to the device may occur If the deadbolt door strike load exceeds 1A an external relay must be used The internal relay is designed for 100 000 cycles If more cycles are needed an external relay dr...

Страница 18: ...Boot Assistant IDEMIA 2017_2000024419 V4 18 Main settings managed by FBA Date Time Time Zone Settings Trigger Event select event s to be processed as an access request by a user Language Settings use...

Страница 19: ...345 For security reasons it is highly recommended to change the devices default password to a custom password Exit or Go Home Validation or confirmation Cancel or refuse Back and Cancel User managemen...

Страница 20: ...s terminal can be configured using a dedicated Windows application MorphoBioToolBox Please note that this application has an embedded User Guide Help menu North and South America E mail support bioter...

Страница 21: ...mbedded Web server enables easy configuration of the devices as well as user enrolment using a web browser on a Desktop PC Laptop Tablet or smart phone The connection to the embedded Webserver through...

Страница 22: ...rsion 11 or higher When Legacy Morpho mode enabled the terminal is compatible with MEMS version 7 3 1 or higher The limitations in Morpho Legacy mode are described in the following document MorphoAcce...

Страница 23: ...record to be added in the local database with the option of creating a user RF card with the user s reference data Enrolment gathering user s data listed below depending on features enabled in the ter...

Страница 24: ...nger as alternative 2nd choice 3rd choice avoid little finger poor fingerprint avoid thumb best accuracy but ergonomically more difficult to use Fingerprint image too dark the finger is probably too m...

Страница 25: ...r Angle IDEAL POSITION Incorrect Position Do not place the finger tip on the bottom of the sensor or in the middle of the sensor Correct Position Align centre of finger tip with sensor centre Incorrec...

Страница 26: ...IDEAL POSITION Finger rotation IDEAL POSITION Incorrect Position Do not leave the finger in the air Do not bend finger upward or downward Correct Position Finger is parallel to sensor surface Incorre...

Страница 27: ...nd starts the authentication process as defined by the terminal settings Contactless Card Position PIN input IDEMIA 2017_2000024419 V4 27 Contactless Card Position Input PIN When defined by terminal s...

Страница 28: ...rmation is provided by the user through a specific screen displayed during identification or authentication process The new screen contains 4 dedicated function keys Entry Exit Beginning of a task End...

Страница 29: ...after significant changes in the database add remove or modification of user s records on a external support such a mass storage key Micro SD Card The micro SD card is linked to the terminal it shall...

Страница 30: ...uide Ref 2017_2000024583 This document contains the full description of all the terminal configuration parameters Documents for the developer MorphoAccess SIGMA Extreme Series Host System Interface Sp...

Страница 31: ...GMA Extreme Documents in the subject line Other countries please visit our web site www biometric terminals com To get your log in and password please contact your sales representative Copyright 2017...

Отзывы: