![Omron E5C series User Manual Download Page 360](http://html.mh-extra.com/html/omron/e5c-series/e5c-series_user-manual_742592360.webp)
A Appendices
A - 34
E5@C Digital Temperature Controllers User’s Manual (H174)
A-7
Sensor Input Setting Range,
Indication Range, Control Range
• The default is 5.
• The applicable standards for each of the above input ranges are as follows:
K, J, T, E, N, R, S, B: JIS C1602-1995, IEC 60584-1
L: Fe-CuNi, DIN 43710-1985
U: Cu-CuNi, DIN 43710-1985
W: W5Re/W26Re, ASTM E988-1990
JPt100: JIS C 1604-1989, JIS C 1606-1989
Pt100: JIS C 1604-1997, IEC 60751
PLII: According to Platinel II Electromotive Force Table by Engelhard Corp.
Specifica
tions
Set
value
Input setting range
Input indication range
Resistance
thermometer
Pt100
0
−
200 to 850 (
°
C)/
−
300 to 1500 (
°
F)
−
220 to 870 (
°
C)/
−
340 to 1540 (
°
F)
1
−
199.9 to 500.0 (
°
C)/
−
199.9 to 900.0 (
°
F)
−
199.9 to 520.0 (
°
C)/
−
199.9 to 940.0 (
°
F)
2
0.0 to 100.0 (
°
C)/0.0 to 210.0 (
°
F)
−
20.0 to 120.0 (
°
C)/
−
40.0 to 250.0 (
°
F)
JPt100
3
−
199.9 to 500.0 (
°
C)/
−
199.9 to 900.0 (
°
F)
−
199.9 to 520.0 (
°
C)/
−
199.9 to 940.0 (
°
F)
4
0.0 to 100.0 (
°
C)/0.0 to 210.0 (
°
F)
−
20.0 to 120.0 (
°
C)/
−
40.0 to 250.0 (
°
F)
Thermocouple
K
5
−
200 to 1300 (
°
C)/
−
300 to 2300 (
°
F)
−
220 to 1320 (
°
C)/
−
340 to 2340 (
°
F)
6
−
20.0 to 500.0 (
°
C)/0.0 to 900.0 (
°
F)
−
40.0 to 520.0 (
°
C)/
−
40.0 to 940.0 (
°
F)
J
7
−
100 to 850 (
°
C)/
−
100 to 1500 (
°
F)
−
120 to 870 (
°
C)/
−
140 to 1540 (
°
F)
8
−
20.0 to 400.0 (
°
C)/0.0 to 750.0 (
°
F)
−
40.0 to 420.0 (
°
C)/
−
40.0 to 790.0 (
°
F)
T
9
−
200 to 400 (
°
C)/
−
300 to 700 (
°
F)
−
220 to 420 (
°
C)/
−
340 to 740 (
°
F)
10
−
199.9 to 400.0 (
°
C)/
−
199.9 to 700.0 (
°
F)
−
199.9 to 420.0 (
°
C)/
−
199.9 to 740.0 (
°
F)
E
11
−
200 to 600 (
°
C)/
−
300 to 1100 (
°
F)
−
220 to 620 (
°
C)/
−
340 to 1140 (
°
F)
L
12
−
100 to 850 (
°
C)/
−
100 to 1500 (
°
F)
−
120 to 870 (
°
C)/
−
140 to 1540 (
°
F)
U
13
−
200 to 400 (
°
C)/
−
300 to 700 (
°
F)
−
220 to 420 (
°
C)/
−
340 to 740 (
°
F)
14
−
199.9 to 400.0 (
°
C)/
−
199.9 to 700.0 (
°
F)
−
199.9 to 420.0 (
°
C)/
−
199.9 to 740 (
°
F)
N
15
−
200 to 1300 (
°
C)/
−
300 to 2300 (
°
F)
−
220 to 1320 (
°
C)/
−
340 to 2340 (
°
F)
R
16
0 to 1700 (
°
C)/0 to 3000 (
°
F)
−
20 to 1720 (
°
C)/
−
40 to 3040 (
°
F)
S
17
0 to 1700 (
°
C)/0 to 3000 (
°
F)
−
20 to 1720 (
°
C)/
−
40 to 3040 (
°
F)
B
18
100 to 1800 (
°
C)/300 to 3200 (
°
F)
0 to 1820 (
°
C)/0 to 3240 (
°
F)
W
19
0 to 2300 (
°
C)/0 to 3200 (
°
F)
−
20 to 2320 (
°
C)/
−
40 to 3240 (
°
F)
PLII
20
0 to 1300 (
°
C)/0 to 2300 (
°
F)
−
20 to 1320 (
°
C)/
−
40 to 2340 (
°
F)
ES1B Infrared
Temperature
Sensor
10 to 70
°
C
21
0 to 90 (
°
C)/0 to 190 (
°
F)
−
20 to 130 (
°
C)/
−
40 to 270 (
°
F)
60 to
120
°
C
22
0 to 120 (
°
C)/0 to 240 (
°
F)
−
20 to 160 (
°
C)/
−
40 to 320 (
°
F)
115 to
165
°
C
23
0 to 165 (
°
C)/0 to 320 (
°
F)
−
20 to 205 (
°
C)/
−
40 to 400 (
°
F)
140 to
260
°
C
24
0 to 260 (
°
C)/0 to 500 (
°
F)
−
20 to 300 (
°
C)/
−
40 to 580 (
°
F)
Current input
4 to 20
mA
25
Any of the following ranges, by scaling:
−
1999 to 9999
−
199.9 to 999.9
−
19.99 to 99.99
−
1.999 to 9.999
−
5% to 105% of setting range. The display shows
−
1999 to 9999 (numeric range with decimal point
omitted).
0 to 20
mA
26
Voltage input
1 to 5 V
27
0 to 5 V
28
0 to 10 V
29
Summary of Contents for E5C series
Page 2: ......
Page 18: ...Conventions Used in This Manual 16 E5 C Digital Temperature Controllers User s Manual H174 ...
Page 34: ...1 Introduction 1 10 E5 C Digital Temperature Controllers User s Manual H174 ...
Page 310: ...6 Parameters 6 94 E5 C Digital Temperature Controllers User s Manual H174 ...
Page 326: ...7 User Calibration 7 16 E5 C Digital Temperature Controllers User s Manual H174 ...
Page 364: ...A Appendices A 38 E5 C Digital Temperature Controllers User s Manual H174 ...
Page 365: ...Index 1 E5 C Digital Temperature Controllers User s Manual H174 I Index ...
Page 370: ...Index 6 E5 C Digital Temperature Controllers User s Manual H174 ...