4 Basic Operation
E5@C Digital Temperature Controllers User’s Manual (H174)
4-13 Cu
sto
m
izing
th
e PV/S
P
D
ispla
y
4
4-13-1 PV/SP Disp
la
y Selections
4-13 Customizing the PV/SP Display
The following table shows the contents of the No. 1, 2, and 3 displays, according to the setting of the
PV/SP Display Screen Selection parameter.
The following table shows the contents of the No. 1, 2, and 3 displays, according to the setting of the
PV/SP Display Screen Selection parameter in the Advanced Function Setting Level.
*
The set value of the Alarm Value 1 parameter is displayed even if it is not valid due to the setting of the
Alarm 1 Type parameter.
During temperature input, the decimal point position depends on the currently selected sensor, and dur-
ing analog input it depends on the Decimal Point parameter setting.
PV/SP Display Selections
*
The default is 1 for models other than the E5
@
C-
@
-0
@
.
z
MV Displays for Heating and Cooling Control (Not Supported for
Position-proportional Models.)
Select either the manipulated variable for heating or the manipulated variable for cooling as the MV
to be displayed for PV/SP/MV during heating and cooling control. The MV Display Selection
parameter is displayed only when heating/cooling control is being performed and PV/SP/MV is
selected in the PV/SP Display Screen parameter or a Monitor/Setting Item Display parameter.
4-13-1 PV/SP Display Selections
Set value
No. 1 display
No. 2 display
No. 3 display (E5EC/E5AC only)
0
Nothing is displayed.
Nothing is displayed.
Nothing is displayed.
1
PV
SP
Nothing is displayed.
2
PV
Nothing is displayed.
Nothing is displayed.
3
SP
SP (character display)
Nothing is displayed.
4
PV
SP
MV
(Valve opening for Position-proportional
Models)
5
PV
SP
Multi-SP No.
6
PV
SP
Soak Time Remain
7
PV
SP
Internal Set Point (ramp SP)
8
PV
SP
Alarm Value 1*
Monitoring range
Unit
PV
Temperature input: The specified range for the specified sensor.
Analog input: Scaling lower limit
−
5%FS to Scaling upper limit +5%FS
EU
Setting (monitoring) range
Unit
SP
SP lower limit to SP upper limit
EU
Code
Parameter
Default
Level
spd1
PV/SP No. 1 Display Selection
4*
Advanced Function Setting
Level
spd2
PV/SP No. 2 Display Selection
0
000
Summary of Contents for E5C series
Page 2: ......
Page 18: ...Conventions Used in This Manual 16 E5 C Digital Temperature Controllers User s Manual H174 ...
Page 34: ...1 Introduction 1 10 E5 C Digital Temperature Controllers User s Manual H174 ...
Page 310: ...6 Parameters 6 94 E5 C Digital Temperature Controllers User s Manual H174 ...
Page 326: ...7 User Calibration 7 16 E5 C Digital Temperature Controllers User s Manual H174 ...
Page 364: ...A Appendices A 38 E5 C Digital Temperature Controllers User s Manual H174 ...
Page 365: ...Index 1 E5 C Digital Temperature Controllers User s Manual H174 I Index ...
Page 370: ...Index 6 E5 C Digital Temperature Controllers User s Manual H174 ...