![Omron E5C series User Manual Download Page 27](http://html.mh-extra.com/html/omron/e5c-series/e5c-series_user-manual_742592027.webp)
1 - 3
1 Introduction
E5@C Digital Temperature Controllers User’s Manual (H174)
1-1 Ap
pearan
ce
, F
eatu
res, an
d
Fun
ctio
ns o
f t
h
e E5
@
C
1
1-1-3
Main F
unctions
Digit shift:
When setting the SP or other parameters, you can use a Shift Key (assigned to the PF Key)
to shift the digit that is being set to aid changing the set values.
This port allows you to change or set parameters from the Setup Tool even when the Controller is
installed in a panel.
For details on particular functions and how to use them, refer to Section 3 Part Names and Basic Proce-
dures and following sections.
z
Input Sensor Types
You can connect the following sensors and signals to the universal input.
z
Control Outputs
• A control output can be a relay output, voltage output (for driving SSR), or linear current output,
depending on the model.
z
Adjusting PID Constants
• You can easily set the optimum PID constants by performing AT (auto-tuning) with the limit cycle
method or by performing ST (self-tuning) with the step response method.
• You can also add RT (robust tuning) to give priority to controlling stability.
z
Alarms
Standard Alarms
• You can output an alarm when the deviation, process value, set point, or manipulated value
reaches a specified value.
• You can also output alarms for the PV rate of change and for loop burnouts.
• If necessary, a more comprehensive alarm function can be achieved by setting a standby
sequence, alarm hysteresis, auxiliary output close in alarm/open in alarm, alarm latch, alarm ON
delay, and alarm OFF delay.
HB and HS Alarms
• With models with the optional HB and HS alarms, you can detect heater burnout and heater short
alarms based on CT inputs.
Integrated Alarm
• You can output an integrated alarm if a standard alarm, HB alarm, or HS alarm turns ON.
Easier Numeric Inputs with a Digit Shift Key
Setup Tool Port on Front Panel of the E5EC/E5AC/E5DC
1-1-3
Main Functions
Thermocouple (temperature input):
K, J, T, E, L, U, N, R, S, B, W, PLII
Resistance thermometer (temperature input):
Pt100, JPt100
Infrared Temperature Sensor (temperature input):
ES1B
10 to 70
°
C, 60 to 120
°
C, 115 to 165
°
C, 140 to 260
°
C
Current input (analog input):
4 to 20 mA DC, 0 to 20 mA DC
Voltage input (analog input):
1 to 5 VDC, 0 to 5 V DC, 0 to 10 V DC
000
000
Summary of Contents for E5C series
Page 2: ......
Page 18: ...Conventions Used in This Manual 16 E5 C Digital Temperature Controllers User s Manual H174 ...
Page 34: ...1 Introduction 1 10 E5 C Digital Temperature Controllers User s Manual H174 ...
Page 310: ...6 Parameters 6 94 E5 C Digital Temperature Controllers User s Manual H174 ...
Page 326: ...7 User Calibration 7 16 E5 C Digital Temperature Controllers User s Manual H174 ...
Page 364: ...A Appendices A 38 E5 C Digital Temperature Controllers User s Manual H174 ...
Page 365: ...Index 1 E5 C Digital Temperature Controllers User s Manual H174 I Index ...
Page 370: ...Index 6 E5 C Digital Temperature Controllers User s Manual H174 ...