I/O Memory Allocation
Section 9-3
204
CS/CJ-series PLC
CX-Simulator
Item
Settings Function
Settings
Function
Instruction Error Op-
eration
0: Continue
1: Stop
Default: 0
This setting determines whether
instruction errors (instruction
processing errors (ER) and illegal
access errors (AER)) are treated
as non-fatal or fatal errors. When
this setting is set to 1, CPU Unit
operation will be stopped if the
ER or AER Flags is turned ON
(even when the AER Flag is
turned ON for an in direct DM/EM
BCD error).
Related Flags: A29508 (Instruc-
tion Processing Error Flag)
A29509 (Indirect DM/EM BCD
Error Flag)
A29510 (Illegal Access Error
Flag)
Same as
CS/CJ-series
PLC.
Minimum Cycle Time
0001 to 7D00:
1 to 32,000 ms
(1-ms units)
Default: 0000
(No minimum)
Set to 0001 to 7D00 to specify a
minimum cycle time. If the cycle
time is less than this setting, it will
be extended until this time
passes. Leave this setting at
0000 for a variable cycle time.
Same as
CS/CJ-series
PLC.
Enable
Watch Cy-
cle Time
Setting
0: Default
1: Bits 0 to 14
Default: 0
Set to 1 to enable the Watch
Cycle Time Setting in bits 0 to 14.
Leave this setting at 0 for a
maximum cycle time of 1 s.
Same as
CS/CJ-series
PLC.
Watch
Cycle
Time
Watch Cy-
cle Time
Setting
001 to FA0: 10 to
40,000 ms
(10-ms units)
Default: 001 (1 s)
This setting is valid only when bit
15 of 209 is set to 1. The Cycle
Time Too Long Flag (A40108) will
be turned ON if the cycle time
exceeds this setting.
Same as
CS/CJ-series
PLC.
Enable
Fixed Ser-
vicing Time
0: Default*
1: Bits 0 to 7
Default: 0
Set to 1 to enable the fixed pe-
ripheral servicing time in bits 0 to
7.
*Default: 4% of the cycle time
Not used.
Fixed
Periph-
eral Ser-
vicing
Time
Fixed Ser-
vicing Time
00 to FF:
0.0 to 25.5 ms
(0.1-ms units)
Default: 00
This setting is valid only when bit
15 of 218 is set to 1.
Not used.
Power OFF Interrupt
Task
0: Disabled
1: Enabled
Default: 0
When this setting is set to 1, the
power OFF interrupt task will be
executed when power is inter-
rupted.
Same as
CS/CJ-series
PLC.
Power OFF Detection
Delay Time
00 to 0A:
0 to 10 ms (1-ms
units)
Default: 00
This setting determines how
much of a delay there will be from
the detection of a power interrup-
tion (approximately 10 to
25 ms after the power supply
voltage drops below 85% of the
rated value) to the confirmation of
a power interruption. The de-fault
setting is 0 ms.
Not used.
Summary of Contents for CX-Simulator 1.9
Page 1: ...Cat No W366 E1 10 CX Simulator Ver 1 9 SYSMAC WS02 SIMC1 E OPERATION MANUAL...
Page 2: ......
Page 3: ...SYSMAC WS02 SIMC1 E CX Simulator Ver 1 9 Operation Manual Revised December 2009...
Page 24: ...xxv...
Page 30: ...xxxi...
Page 35: ...xxxvi...
Page 39: ......
Page 63: ...Comparison of the CX Simulator and SYSMAC CS CJ series PLCs Section 1 6 24...
Page 75: ...Installing and Uninstalling the Software Section 2 1 36...
Page 157: ...Task Debugging Section 4 4 118...
Page 195: ...Connection with Application Programs Section 7 2 156...
Page 225: ...Checking the Result Section 8 5 186...
Page 277: ...Other Functions Section 9 4 238...
Page 289: ...Other Tips for Troubleshooting Section 10 3 250...
Page 304: ......
Page 305: ......