I/O Memory Allocation
Section 9-3
202
CS/CJ-series PLC
CX-Simulator
Item
Settings Function
Settings
Function
Communi-
cations rate
(bps)
00: 9,600
01: 300
02: 600
03: 1,200
04: 2,400
05: 4,800
06: 9,600
07: 19,200
08: 38,400
09: 57,600
0A: 115,200
Default: 00
Settings 00 and 06 through 0A
are valid when the communica-
tions mode is set to peripheral
bus.
This setting is not valid when the
communications mode is set to
NT Link.
CPU Unit’s
Unit Num-
ber in Host
Link Mode
00 to 1F
(0 to 31)
Default: 00
This setting determines the CPU
Unit’s unit number when it is
connected in a 1-to-N (N=2 to 32)
host link.
Periph-
eral Port
Settings
Maximum
Unit Num-
ber in NT
Link Mode
0 to 7
Default: 0
This setting determines the high-
est unit number of PT that can be
connected to the PLC in NT Link
mode.
Not used.
RS-232C
Port Set-
tings Selec-
tion
0: Default*
1: PLC Setup
Default: 0
This setting is effective only when
pin 5 of the DIP switch on the
front of the CPU Unit is OFF.
*The default settings are: host
link mode, 1 start bit, 7 data bits,
even parity, 2 stop bits, and a
baud rate of 9,600 bps.
Not used.
Communi-
cations
mode
00: Host link
02: NT link
(1: N mode)
03: No-protocol
04: Peripheral
bus
05: Host link
Default: 0
This setting determines whether
the RS-232C port will operate in
host link mode or another serial
communications mode. (Host link
can be specified with 00 or
05.)The Peripheral bus mode is
for communications with Pro-
gramming Devices other than the
Programming Console.
Same as
CS/CJ-series
PLC.
When
No-protocol is
set, the
RS-232C
Send Ready
Flag (A39205)
turns ON.
Data bits
0: 7 bits
1: 8 bits
Default: 0
Same as
CS/CJ-series
PLC.
Stop bits
0: 2 bits
1: 1 bit
Default: 0
Same as
CS/CJ-series
PLC.
RS-232C
Port
Set-tings
Parity 00:
Even
01: Odd
10: None
Default: 00
These settings are valid only
when the communications mode
is set to host link or no-protocol.
These settings are also valid only
when the RS-232C Port Settings
Selection is set to 1: PLC Setup.
Same as
CS/CJ-series
PLC.
Summary of Contents for CX-Simulator 1.9
Page 1: ...Cat No W366 E1 10 CX Simulator Ver 1 9 SYSMAC WS02 SIMC1 E OPERATION MANUAL...
Page 2: ......
Page 3: ...SYSMAC WS02 SIMC1 E CX Simulator Ver 1 9 Operation Manual Revised December 2009...
Page 24: ...xxv...
Page 30: ...xxxi...
Page 35: ...xxxvi...
Page 39: ......
Page 63: ...Comparison of the CX Simulator and SYSMAC CS CJ series PLCs Section 1 6 24...
Page 75: ...Installing and Uninstalling the Software Section 2 1 36...
Page 157: ...Task Debugging Section 4 4 118...
Page 195: ...Connection with Application Programs Section 7 2 156...
Page 225: ...Checking the Result Section 8 5 186...
Page 277: ...Other Functions Section 9 4 238...
Page 289: ...Other Tips for Troubleshooting Section 10 3 250...
Page 304: ......
Page 305: ......