![background image](http://html1.mh-extra.com/html/omron/cx-simulator-1-9/cx-simulator-1-9_operation-manual_744207205.webp)
Generating Virtual External Inputs
Section 8-3
166
8-3-2 Data Trace File
The time-series data (Data Trace File) of I/O memory area acquired from an
actual PLC can be replayed on the Ladder Engine using the Data Replay Tool.
Note
Refer to
8-4
Running by Virtual External Inputs
for replaying by Data Replay
Tool.
Create a Data Trace File using the data trace or the time chart monitor of the
CX-Programmer, or Data Trace Recording Tool for long-term data.
Creating Data Trace Data using CX-Programmer
Use the Data Trace File (.cdt) created in the data trace or the time chart
monitor of the CX-Programmer for the data of data trace.
Set necessary data using the CX-Programmer and execute the data trace or
the time chart monitor on the CS/CJ/CP-series CPU Unit. The result will be
saved as a file and operation by virtual external inputs will be performed.
Note
1. All data of the Data Trace File is regarded as data for input, fed to the
Ladder Engine. When setting for I/O memory areas that will be sampled
in the CX-Programmer, make sure they can be used as inputs.
2. Refer to the
Data Trace/Time Chart Monitoring
of
CHAPTER 4 - Refer-
ence
of
PART 1: CX-Programmer
in the
CX-Programmer Operation
Manual
(W446) for how to operate the data trace and time chart moni-
toring.
Replaying Data of Data Trace
The data of the data trace differs in replay timing depending on the sampling
setting when saving. In addition, all saved data is replayed regardless of the
trigger setting.
Replay
timing
(Synchronous)
Replay timing
(Asynchronous)
Every cycle
Every cycle
Fixed interval
Regular sampling
Sampling interval
Sampling interval
Sampling by the TRSM Every cycle
Fixed interval
Note
Some data of the data trace with short sampling cycle can not be replayed in
the timing of the sampling cycle if replayed asynchronously. Furthermore, the
data with a sampling cycle shorter than that when replaying can not be re-
played.
Saving Long-term Data with Data Trace Recording Tool
A Data Trace File can contain up to 32,762 sets of data.
When more data or long-term trace data is required, it can be saved in multiple
Data Trace Files by using the Data Trace Recording Tool attached to the
CX-Simulator.
Note
Refer to
Appendix
How to Use Data Trace Recording Tool
for how to use the
Data Trace Recording Tool.
Summary of Contents for CX-Simulator 1.9
Page 1: ...Cat No W366 E1 10 CX Simulator Ver 1 9 SYSMAC WS02 SIMC1 E OPERATION MANUAL...
Page 2: ......
Page 3: ...SYSMAC WS02 SIMC1 E CX Simulator Ver 1 9 Operation Manual Revised December 2009...
Page 24: ...xxv...
Page 30: ...xxxi...
Page 35: ...xxxvi...
Page 39: ......
Page 63: ...Comparison of the CX Simulator and SYSMAC CS CJ series PLCs Section 1 6 24...
Page 75: ...Installing and Uninstalling the Software Section 2 1 36...
Page 157: ...Task Debugging Section 4 4 118...
Page 195: ...Connection with Application Programs Section 7 2 156...
Page 225: ...Checking the Result Section 8 5 186...
Page 277: ...Other Functions Section 9 4 238...
Page 289: ...Other Tips for Troubleshooting Section 10 3 250...
Page 304: ......
Page 305: ......