3-9-8 Task Control Window
The Task Control window displays the status of the task in the program area
for application programs (UM1).
Names and Functions
Name Function
Main menu
Select a menu.
Change task display Select the task to be displayed from the tasks regis-
tered in the program (Cycle, interrupt, or All tasks).
Task type display
Display the task type (Cycle execution task or interrupt
task). If multiple interrupt types are set to a single in-
terrupt task, they will be displayed as separate lines.
Task No. display
Display the task No. of cycle tasks and interrupt tasks.
Task settings display For the cyclic task, display "Cycle." For the interrupt
task, display its interrupt type (Power interrupt, sched-
uled interrupt, I/O interrupt, or External interrupt).
Task startup interval Display the time (unit: ms) for the clock interrupt task.
Task status display
For a cyclic task, display the execution status (Initial,
Ready, Run, or Wait). For an interrupt task, display
“Run” if it is being executed and nothing if it is not.
Task execution count Display the count for each task after the Ladder Engine
is started or reset.
Task execution time
Display the time required to execute each task (The
latest value, Unit: ms). If an interrupt task is executed
while executing the cyclic task, the execution time for
the interrupt task is also added. If set as the computer
cycle time, the standby time for pausing with Step Run
and Scan Run is added, too.
Monitor button
Switch between update (monitoring) and not update
(stop monitoring) of the window.
[Close] button
Exit the Task Control window.
Change task
display
Task type
display
Task No. display
Task settings
display
[Close] button
Main menu
Task execution
time
Task execution
count
Task status
display
Task startup in-
terval
Monitor button
Summary of Contents for CX-Simulator 1.9
Page 1: ...Cat No W366 E1 10 CX Simulator Ver 1 9 SYSMAC WS02 SIMC1 E OPERATION MANUAL...
Page 2: ......
Page 3: ...SYSMAC WS02 SIMC1 E CX Simulator Ver 1 9 Operation Manual Revised December 2009...
Page 24: ...xxv...
Page 30: ...xxxi...
Page 35: ...xxxvi...
Page 39: ......
Page 63: ...Comparison of the CX Simulator and SYSMAC CS CJ series PLCs Section 1 6 24...
Page 75: ...Installing and Uninstalling the Software Section 2 1 36...
Page 157: ...Task Debugging Section 4 4 118...
Page 195: ...Connection with Application Programs Section 7 2 156...
Page 225: ...Checking the Result Section 8 5 186...
Page 277: ...Other Functions Section 9 4 238...
Page 289: ...Other Tips for Troubleshooting Section 10 3 250...
Page 304: ......
Page 305: ......