Error Processing
Section 10-1
244
Symptoms Causes
Remedies
The specified output file could not
be generated from the template
file. Operation exit.
The file does not
exist or has a
wrong format.
Specify a Data Replay file or a template file of a cor-
rect format.
The specified output file does not
exist or its data is invalid. Opera-
tion exit
The file does not
exist or has a
wrong format.
Specify a Data Replay file (CSV text file) of a correct
format, which is different from an execution file of the
I/O Condition Tool.
The target PLC was switched
from CX-Simulator to an actual
PLC. Operation exit.
The target PLC
was changed
while data replay-
ing.
The target PLC can not be changed while replaying
data.
10-1-5 Data Trace Recording Tool
If an error occurs while operating the
Data Trace Recording Tool,
the error
contents will be displayed in the dialog box. Remove the error causes referring
to the remedies.
Symptoms Causes
Remedies
--: Address(**) of bit area is out
of range.
Correct the address referring to Appendix: Dialog box
for editing the address to be sampled.
--: Address(**) of word area is
out of range.
Correct the address referring to Appendix: Dialog box
for editing the address to be sampled.
Cannot connect to PLC. PLC
communications error --.
The target PLC
does not exist.
Check the FINS address for the target PLC.
Data Trace was started in man-
ual mode, failed to start in auto
mode.
Not possible of
automatic saving by
the command line.
Create the setting file again and start by the com-
mand line.
Failed to execute Data Trace.
Because the parameters of the
file to be added are different
from setting parameters.
1. Specify the same values as the saved parame-
ters.
2. Remove the check mark of "Add saving" and try
again.
Failed to stop Data Trace.
Communications
disabled during
Data Trace.
Restore to able-to-communicate state and try again.
Failed to open the destination
file for adding the Trace data.
The file format is
wrong when speci-
fying "Add saving."
Specify another file name when Add saving and try
again. Remove the check mark of "Add saving."
Failed to save the sampling data
to --.
Wrong path name,
The file being used,
Read-only file, or
Low disk space
1. Check if the path name is correct.
2. Check if another application is using the file.
3. Check if read-only or the user is authorized to
write.
4. Check if disk space is enough.
Failed to start Timer.
32 Windows timers
are exhausted in
the whole system.
Exit some applications and try again.
Sampling area is not specified.
Register at least one address to either of word/bit
address.
Specified PLC type -- is not
supported. Data Trace will not
start.
The target PLC
specifies other than
CS/CJ/CP Series.
Specify CS/CJ/CP Series as a target PLC.
The data of the setting file -- is
invalid.
The contents of the
setting file are
wrong.
Create the setting file by [Parameters Save] again.
Summary of Contents for CX-Simulator 1.9
Page 1: ...Cat No W366 E1 10 CX Simulator Ver 1 9 SYSMAC WS02 SIMC1 E OPERATION MANUAL...
Page 2: ......
Page 3: ...SYSMAC WS02 SIMC1 E CX Simulator Ver 1 9 Operation Manual Revised December 2009...
Page 24: ...xxv...
Page 30: ...xxxi...
Page 35: ...xxxvi...
Page 39: ......
Page 63: ...Comparison of the CX Simulator and SYSMAC CS CJ series PLCs Section 1 6 24...
Page 75: ...Installing and Uninstalling the Software Section 2 1 36...
Page 157: ...Task Debugging Section 4 4 118...
Page 195: ...Connection with Application Programs Section 7 2 156...
Page 225: ...Checking the Result Section 8 5 186...
Page 277: ...Other Functions Section 9 4 238...
Page 289: ...Other Tips for Troubleshooting Section 10 3 250...
Page 304: ......
Page 305: ......