I/O Memory Allocation
Section 9-3
231
Address CS/CJ-series
PLC
CX-Simulator
Words Bits
Name
Function Settings
Function
Settings
A50014 Error
Log
Reset Bit
Turn this bit ON to reset the
Error Log Pointer (A300) to 00.
The contents of the Error Log
Area itself (A100 to A199) are
not cleared. These words can be
cleared from a Programming
Device or by writing 0000 to all
of the words.
(This bit is automatically reset to
0 after the Error Log Pointer is
reset.)
0
Æ
1: Clear
Same as
CS/CJ-series
PLC.
Not reset
in the
Program
mode.
A500
A50015 Output
OFF
Bit
Turn this bit ON to turn OFF all
outputs from Basic I/O Units and
Special I/O Units.
Not
used.
A501 A50100
to
A50115
CS/CJ-series
CPU Bus Unit
Restart Bits
Turn these bits ON to restart
(initialize) the CS/CJ-series
CPU Bus Unit with the corre-
sponding unit number. Bits 00 to
15 correspond to unit numbers 0
to F.
When a restart bit is turned ON,
the corresponding CS/CJ-series
CPU Bus Unit Initializing Flag
(A30200 to A30215) will be
turned ON. Both the restart bit
and initializing flag will be turned
OFF automatically when ini-
tialization is completed.
0 to 1: Re-
start
1 to 0: Re-
start com-
pleted
Turned OFF
by the sys-
tem when
the Unit has
been re-
started.
Not used.
A502 to
A507
A50200
to
A50715
Special I/O
Unit Restart
Bits
Turn these bits ON to restart
(initialize) the Special I/O Unit
with the corresponding unit
number.
0 to 1: Re-
start
1 to 0: Re-
start com-
pleted
Turned OFF
by the sys-
tem when
the Unit has
been re-
started.
Not used.
A50809 Differentiate
Monitor Com-
pleted Flag
ON when the differentiate
monitor condition has been
established during execution of
differentiation monitoring.
(This flag will be cleared to 0
when differentiation monitoring
starts.)
1: Monitor
condition
established
0: Not yet
established
Same as
CS/CJ-series
PLC.
A508
A50811 Trace
Trigger
Monitor Flag
ON when a trigger condition is
established by the Trace Start
Bit (A50814). OFF when the
next Data Trace is started by the
Sampling Start Bit (A50815).
1: Trigger
condition
established
0: Not yet
established
or not tracing
Same as
CS/CJ-series
PLC.
Summary of Contents for CX-Simulator 1.9
Page 1: ...Cat No W366 E1 10 CX Simulator Ver 1 9 SYSMAC WS02 SIMC1 E OPERATION MANUAL...
Page 2: ......
Page 3: ...SYSMAC WS02 SIMC1 E CX Simulator Ver 1 9 Operation Manual Revised December 2009...
Page 24: ...xxv...
Page 30: ...xxxi...
Page 35: ...xxxvi...
Page 39: ......
Page 63: ...Comparison of the CX Simulator and SYSMAC CS CJ series PLCs Section 1 6 24...
Page 75: ...Installing and Uninstalling the Software Section 2 1 36...
Page 157: ...Task Debugging Section 4 4 118...
Page 195: ...Connection with Application Programs Section 7 2 156...
Page 225: ...Checking the Result Section 8 5 186...
Page 277: ...Other Functions Section 9 4 238...
Page 289: ...Other Tips for Troubleshooting Section 10 3 250...
Page 304: ......
Page 305: ......