![background image](http://html1.mh-extra.com/html/omron/cx-simulator-1-9/cx-simulator-1-9_operation-manual_744207105.webp)
System Status Setting Window
Section
3-7
66
1,2,3…
1. Selecting [UM Settings] in the [System Status Setting] | [Settings] menu will
display the [UM Settings] window.
•
UM Access Enable
Set the UM for downloading/uploading and
editing online by the CX-Programmer.
•
UM Execution Enable
Set whether to execute programs on the UM
(enable) or not. Disabling both of UM1 and UM2
simultaneously is not possible.
•
OK
Save the current settings and exit the window.
•
Cancel
Discard the current settings and exit the win-
dow.
2. Click the [OK] button when UM setting is completed.
Note
Refer to
8 Debugging Using Virtual External Inputs
for how to use the UM2.