I/O Memory Allocation
Section 9-3
232
Address CS/CJ-series
PLC
CX-Simulator
Words Bits
Name
Function Settings
Function
Settings
A50812 Trace
Completed
Flag
ON when sampling of a region of
trace memory has been com-
pleted during execution of a
Trace.
OFF when the next time the
Sampling Start Bit (A50815) is
turned from OFF to ON.
1: Trace
completed
0: Not trac-
ing or trace
in progress
Same as
CS/CJ-series
PLC.
A50813 Trace
Busy
Flag
ON when the Sampling Start Bit
(A50815) is turned from OFF to
ON. OFF when the trace is com-
pleted.
1: Trace in
progress
0: Not trac-
ing (not
sampling)
Same as
CS/CJ-series
PLC.
A50814 Trace
Start
Bit
Turn this bit from OFF to ON to
establish the trigger condition.
The offset indicated by the delay
value (positive or negative) de-
termines which data samples are
valid.
1: Trace
trigger con-
dition es-
tablished
0: Not es-
tablished
Same as
CS/CJ-series
PLC.
A508
A50815 Sampling
Start Bit
When a data trace is started by
turning this bit from OFF to ON
from a Programming Device, the
PLC will begin storing data Trace
Memory by one of the three fol-
lowing methods:
1) Data is sampled at regular
intervals (10 to 2,550 ms).
2) Data is sampled when
TRSM(045) is executed in the
program.
3) Data is sampled at the end of
every cycle.
0 to 1:
Starts data
trace (sam-
pling)
Same as
CS/CJ-series
PLC.
A509 A50900
SYSMAC
BUS Slave
Number
Refresh Bit
Turn this bit ON to refresh the
error information in A425 (unit
number of Slave where error
occurred after startup).
Not
used.
A510 to
A511
Start-up
Time
These words contain the time at
which the power was turned ON.
The contents are updated every
time that the power is turned ON.
The data is stored in BCD.
A51000 to A51007:
Second (00 to 59)
A51008 to A51015:
Minute (00 to 59)
A51100 to A51107:
Hour (00 to 23)
A51108 to A51115:
Day of month (01 to 31)
See Func-
tion col-
umn.
Same as
CS/CJ-series
PLC.
Summary of Contents for CX-Simulator 1.9
Page 1: ...Cat No W366 E1 10 CX Simulator Ver 1 9 SYSMAC WS02 SIMC1 E OPERATION MANUAL...
Page 2: ......
Page 3: ...SYSMAC WS02 SIMC1 E CX Simulator Ver 1 9 Operation Manual Revised December 2009...
Page 24: ...xxv...
Page 30: ...xxxi...
Page 35: ...xxxvi...
Page 39: ......
Page 63: ...Comparison of the CX Simulator and SYSMAC CS CJ series PLCs Section 1 6 24...
Page 75: ...Installing and Uninstalling the Software Section 2 1 36...
Page 157: ...Task Debugging Section 4 4 118...
Page 195: ...Connection with Application Programs Section 7 2 156...
Page 225: ...Checking the Result Section 8 5 186...
Page 277: ...Other Functions Section 9 4 238...
Page 289: ...Other Tips for Troubleshooting Section 10 3 250...
Page 304: ......
Page 305: ......