Step Run and Break
Section 4-3
113
Condition Combination
The I/O break condition expression can be set by combining conditions (Turn
on check boxes for conditions registered in AND LIST or OR LIST). The I/O
break condition expression is configured by combining [AND LIST] (Conditions
are combined with AND operators) and [OR LIST] (Conditions are combined
with OR operators) with logical operators (AND/OR). The relationship between
[AND LIST] and [OR LIST] is expressed by the following logic expression.
( [AND LIST] ) AND ( [OR LIST] )
A maximum of 64 items can be registered in AND LIST and OR LIST respec-
tively. Also, a maximum of 64 combinations of logic expressions can be cre-
ated for both the lists together.
I/O break condition setting
expression
(IO0.0=ON and H1.15=ON) and
(DM0>=#7FFF or A401.08=ON)
Summary of Contents for CX-Simulator 1.9
Page 1: ...Cat No W366 E1 10 CX Simulator Ver 1 9 SYSMAC WS02 SIMC1 E OPERATION MANUAL...
Page 2: ......
Page 3: ...SYSMAC WS02 SIMC1 E CX Simulator Ver 1 9 Operation Manual Revised December 2009...
Page 24: ...xxv...
Page 30: ...xxxi...
Page 35: ...xxxvi...
Page 39: ......
Page 63: ...Comparison of the CX Simulator and SYSMAC CS CJ series PLCs Section 1 6 24...
Page 75: ...Installing and Uninstalling the Software Section 2 1 36...
Page 157: ...Task Debugging Section 4 4 118...
Page 195: ...Connection with Application Programs Section 7 2 156...
Page 225: ...Checking the Result Section 8 5 186...
Page 277: ...Other Functions Section 9 4 238...
Page 289: ...Other Tips for Troubleshooting Section 10 3 250...
Page 304: ......
Page 305: ......