Generating Virtual External Inputs
Section 8-3
163
5. Click the [Set All] button if selecting all items registered in the FINS ad-
dress/command filter. Click the [Clear All] if clearing all check items.
6. Selecting the [OK] button will cause the settings valid.
Command Log Save Start/Exit
Set the “Command Log Save Start” after setting the “Command log.”
Start the “Command Log Save” by [CX-Simulator Debug Console] | [Replay] |
[Command log] | [Start]. If exiting or pausing the “Command Log Save,” select
[Stop] in [Debug Console] | [Replay] | [Command log].
FINS Address Filter
Specify the FINS address filter if filtering by the FINS address.
Some FINS addresses for application programs on the computer change
dynamically (FINS addresses of the CX-Programmer change, also.). So usu-
ally use the CX-Simulator in the default setting (FINS address =*.*.*: All
nodes).
When adding items to the list of FINS address filter, input the FINS address to
be added (the network address, node address, and Machine address (Unit
address)) and its name (tentative) followed by the [Add] button.
In specifying the address, an "*" can also be specified. For example, if an "*" is
specified for the Machine address setting, the FINS command to/from the
specified address will be saved as the command log.
When deleting the items in the list of FINS address filter, select the item to be
deleted in the list and click the [Delete] button.
FINS Command Filter
Specify the FINS command filter when filtering by the FINS command. Filtering
is performed by comparing the character string data (hex) from the top of the
FINS command. For example, when writing to the EM area (common), the
filtering pattern will be 01012, saving 010121 (EM area write (Bank 1), 01012A
(EM area write (Bank 10), etc. to the Command Log File.
Refer to
List of Usable FINS Command Filters and Data Replay Possible/Not
possible
for usable FINS command filters and whether the saved data is pos-
sible to be replayed or not.
When adding items to the list of FINS command filter, select the items to be
added (FINS command name) in the dropdown list of the FINS command filter.
When deleting items from the list of FINS command filter, select the items to be
deleted in the list and click the [Delete] button of the FINS command filter.
Note
At least one FINS address/command filter must be set respectively to create
the command log. An error will not occur in the Data Replay Tool even if a filter
that can not be replayed is set.
Note
The details for FINS commands are given in the
Communications Commands
Reference Manual.
Note
The upper limit of the command log file size is 30 MB. If exceeded, the log
data will not be saved after that.
Summary of Contents for CX-Simulator 1.9
Page 1: ...Cat No W366 E1 10 CX Simulator Ver 1 9 SYSMAC WS02 SIMC1 E OPERATION MANUAL...
Page 2: ......
Page 3: ...SYSMAC WS02 SIMC1 E CX Simulator Ver 1 9 Operation Manual Revised December 2009...
Page 24: ...xxv...
Page 30: ...xxxi...
Page 35: ...xxxvi...
Page 39: ......
Page 63: ...Comparison of the CX Simulator and SYSMAC CS CJ series PLCs Section 1 6 24...
Page 75: ...Installing and Uninstalling the Software Section 2 1 36...
Page 157: ...Task Debugging Section 4 4 118...
Page 195: ...Connection with Application Programs Section 7 2 156...
Page 225: ...Checking the Result Section 8 5 186...
Page 277: ...Other Functions Section 9 4 238...
Page 289: ...Other Tips for Troubleshooting Section 10 3 250...
Page 304: ......
Page 305: ......