Alarms and Remedies
Section 10-2
246
Alarms Causes
Remedies
Failed to start the interrupt task (Task
No. -- )
Too high frequency
of starting interrupt
tasks.
Lower the frequency of starting interrupt tasks.
Failed to write command log to the
file.
Short disk space, etc Increase the disk space or change the destination for cre-
ating the log file.
FINS operation was canceled.
Wrong routing in-
formation.
1. [Disconnect] and [Connect] and then try again.
2. Exit the CX-Simulator and restart.
Network communications was not
executed because of setting error of
it.
Wrong routing in-
formation.
1. [Disconnect] and [Connect] and then try again.
2. Exit the CX-Simulator and restart.
Routing table error: Failed to transfer
because the number of local tables
exceeds maximum (16).
Wrong routing in-
formation.
1. [Disconnect] and [Connect] and then try again.
2. Exit the CX-Simulator and restart.
Routing table error: Failed to transfer
because the number of relay tables
exceeds maximum (20).
Wrong routing in-
formation.
1. [Disconnect] and [Connect] and then try again.
2. Exit the CX-Simulator and restart.
Routing table error: The network
address in the local table records
must be 0x00 or over 0x80.
Wrong routing in-
formation.
1. [Disconnect] and [Connect] and then try again.
2. Exit the CX-Simulator and restart.
Routing table error: The unit address
in the local table records must be
under 0x10 or over 0x20.
Wrong routing in-
formation.
1. [Disconnect] and [Connect] and then try again.
2. Exit the CX-Simulator and restart.
Routing table error: The unit address
in the local table records must be
unique.
Wrong routing in-
formation.
1. [Disconnect] and [Connect] and then try again.
2. Exit the CX-Simulator and restart.
Serial communications were not
executed because the target node
was at another network.
Wrong destination
FINS address of the
communications
instruction.
A communications instruction can not be issued to a node of
other than the local network.
The size of memory preservation file
is invalid.
The Value of checksum for the
memory preservation file is incorrect.
The values on the memory (e.g. UM) of the Ladder Engine
are indefinite. Initialize the I/O memory area of the Ladder
Engine following the next procedure.
1. Exit the CX-Simulator.
2. Delete all Memory?.dat files in the PLC data folder
where an error occurred.
3. Restart the CX-Simulator and specify the relevant folder
to start the Ladder Engine.
Summary of Contents for CX-Simulator 1.9
Page 1: ...Cat No W366 E1 10 CX Simulator Ver 1 9 SYSMAC WS02 SIMC1 E OPERATION MANUAL...
Page 2: ......
Page 3: ...SYSMAC WS02 SIMC1 E CX Simulator Ver 1 9 Operation Manual Revised December 2009...
Page 24: ...xxv...
Page 30: ...xxxi...
Page 35: ...xxxvi...
Page 39: ......
Page 63: ...Comparison of the CX Simulator and SYSMAC CS CJ series PLCs Section 1 6 24...
Page 75: ...Installing and Uninstalling the Software Section 2 1 36...
Page 157: ...Task Debugging Section 4 4 118...
Page 195: ...Connection with Application Programs Section 7 2 156...
Page 225: ...Checking the Result Section 8 5 186...
Page 277: ...Other Functions Section 9 4 238...
Page 289: ...Other Tips for Troubleshooting Section 10 3 250...
Page 304: ......
Page 305: ......