Starting and Going Online from the CX-Programmer
Section
3-2
41
Name Function
I/O Condition
Starts the I/O Condition Operation Tool. Refer to
I/O Condition
under
3-9-5 [Replay] Menu
for details.
Data Replay
Sets Data Replay and starts the Data Replay Tool. Refer to
Data Re-
play
under
3-9-5 [Replay] Menu
for details.
PLC Clock Settings
Sets the cycle time mode, the interval for continuous run, and others.
Refer to
3-7-5 PLC Clock Settings
for details.
PLC Operation Settings
Sets the WDT disable, DIP switches, and others. Refer to
3-7-6 PLC
Operation Settings
for details.
Initialize PLC
Initialize the I/O memory of PLC.
Always on Top
Pins the CX-Simulator windows on top.
Help Displays
help.
3-2-3 Disconnecting the CX-Simulator from the CX-Programmer
Use the following procedure to end the online connection to the CX-Simulator
from the CX-Programmer.
Select [Simulation] | [Simulator Online Connection] from the main menus. The
CX-Simulator will go offline and the CX-Simulator dialog box will return to the
task tray. The CX-Simulator will automatically return to PROGRAM mode. The
CX-Simulator dialog box will be restored to the original position if [PLC] |
[Simulator Online Connection] is selected from the main menus of the
CX-Programmer again.
3-2-4 Exiting the CX-Simulator from the CX-Programmer
You can exit the CX-Simulator using any of the following steps.
•
Select [Exit Simulator] from the [Simulation] menu in the main menus of the
CX-Programmer.
•
Close the CX-Programmer project.
•
Exit the CX-Programmer.
3-2-5 Going Online with the CX-Simulator Already Started from
CX-Simulator Menus
[Simulator Online Connection] can be selected to go online with the
CX-Simulator even if the CX-Simulator has already been started from
CX-Simulator menus. To do this, the CX-Simulator Communications Unit must
be the Controller Link.
1,2,3…
1. Open a project on the CX-Programmer and set the PLC model to the same
model as the one used to start the CX-Simulator.
2. Select [Simulation] | [Simulator Online Connection] from the main menus of
the CX-Programmer. An online connect will be made unrelated to the
communications settings in the current project.
Summary of Contents for CX-Simulator 1.9
Page 1: ...Cat No W366 E1 10 CX Simulator Ver 1 9 SYSMAC WS02 SIMC1 E OPERATION MANUAL...
Page 2: ......
Page 3: ...SYSMAC WS02 SIMC1 E CX Simulator Ver 1 9 Operation Manual Revised December 2009...
Page 24: ...xxv...
Page 30: ...xxxi...
Page 35: ...xxxvi...
Page 39: ......
Page 63: ...Comparison of the CX Simulator and SYSMAC CS CJ series PLCs Section 1 6 24...
Page 75: ...Installing and Uninstalling the Software Section 2 1 36...
Page 157: ...Task Debugging Section 4 4 118...
Page 195: ...Connection with Application Programs Section 7 2 156...
Page 225: ...Checking the Result Section 8 5 186...
Page 277: ...Other Functions Section 9 4 238...
Page 289: ...Other Tips for Troubleshooting Section 10 3 250...
Page 304: ......
Page 305: ......