I/O Memory Allocation
Section 9-3
229
Address CS/CJ-series
PLC
CX-Simulator
Words Bits
Name
Function Settings
Function
Settings
A42600
to
A42611
Interrupt Task
Error, Task
Number
When A40213 is ON, the content
of these bits depends upon the
status of A42615 (the Interrupt
Task Error Cause Flag).
1) A42615 OFF:
An interrupt task was executed
for more than 10 ms during I/O
refreshing of a C200H Special
I/O Unit or a SYSMAC BUS
Remote I/O Unit. A42600 to
A42611: contain the interrupt
task number.
2) A42615 ON:
An attempt was made to re-
fresh a Special I/O Unit’s I/O
from an interrupt task with
IORF(097) while the Unit’s I/O
is being refreshed by cyclic I/O
refreshing (duplicate refresh-
ing). A42600 to A42611: con-
tain the Special I/O Unit’s unit
number.
Task num-
ber:
000 to 0FF
(0 to 255)
Unit number:
000 to 05F (0
to 95)
Not used.
A426
A42615 Interrupt
Task
Error Cause
Flag
When A40213 (the Interrupt Task
Error Flag) is ON, this flag indi-
cates the cause of the error.
A42615 will be ON if a Special I/O
Unit was refreshed from the in-
terrupt task while it was already
being refreshed.
A42615 will be OFF if the inter-
rupt task was executed for more
than 10 ms during I/O refreshing
of a C200H Special I/O Unit or a
SYSMAC BUS Remote I/O Unit.
1: Duplicated
refreshing
0: Interrupt
task exe-
cuted over
10 ms
Not used.
A427 A42700
to
A42715
CS/CJ-series
CPU Bus Unit
Setting Error,
Unit Number
Flags
When a CS/CJ-series CPU Bus
Unit Setting Error occurs, A40203
and the bit in this word corre-
sponding to the Unit’s unit num-
ber are turned ON. Bits 00 to 15
correspond to unit numbers 0 to
F.
The CPU Unit will continue oper-
ating and the ERR/ALM indicator
on the front of the CPU Unit will
flash.
1: Setting
error
0: No setting
error
Not used.
A428 to
A433
A42800
to
A43315
Special I/O
Unit Setting
Error, Unit
Number Flags
When a Special I/O Unit Setting
Error occurs, A40202 and the bit
in these words corresponding to
the Unit’s unit number are turned
ON. Bits 00 to 15 correspond to
unit numbers 0 to F.
1: Setting
error
0: No setting
error
Not used.
Summary of Contents for CX-Simulator 1.9
Page 1: ...Cat No W366 E1 10 CX Simulator Ver 1 9 SYSMAC WS02 SIMC1 E OPERATION MANUAL...
Page 2: ......
Page 3: ...SYSMAC WS02 SIMC1 E CX Simulator Ver 1 9 Operation Manual Revised December 2009...
Page 24: ...xxv...
Page 30: ...xxxi...
Page 35: ...xxxvi...
Page 39: ......
Page 63: ...Comparison of the CX Simulator and SYSMAC CS CJ series PLCs Section 1 6 24...
Page 75: ...Installing and Uninstalling the Software Section 2 1 36...
Page 157: ...Task Debugging Section 4 4 118...
Page 195: ...Connection with Application Programs Section 7 2 156...
Page 225: ...Checking the Result Section 8 5 186...
Page 277: ...Other Functions Section 9 4 238...
Page 289: ...Other Tips for Troubleshooting Section 10 3 250...
Page 304: ......
Page 305: ......