![background image](http://html1.mh-extra.com/html/omron/cx-simulator-1-9/cx-simulator-1-9_operation-manual_744207136.webp)
Debug Console Window
Section
3-9
97
Contents of Menu
Name Function
Tasks
Display the task menu.
Help
Display the information on Help and the version.
Menu List of [Step Run] Window
Main Menu
Submenu
Shortcut
Function
Run Mode
Turn the selected cyclic task into the execution
mode.
Wait Mode
Turn the selected cyclic task into the standby
mode.
Cyclic tasks
Block Run
Execute the selected cyclic task in block. Used in
Program mode.
Start
Start the selected task as an extra cyclic task.
Extra cyclic
tasks
Stop
Stops the selected task.
Activate Interrupt Task
In Program mode, execute the selected interrupt
task in block. In Monitor/Run mode, an interrupt
occurs at the moment and the process moves to
the specified interrupt task.
Copy task data
Copy the list of Task Control being displayed to
the clipboard.
Tasks
Exit
Close the Task Control window.
Help Contents
Display the Help Contents
Help Index
Display the Help Index.
Help
About
Display the version information.
Content of Pop-up Menu
Clicking the task line and right-clicking will display the pop-up menu.
Name Function
Execution Mode
Turn the selected cyclic task to Execution mode.
Standby Mode
Turn the selected cyclic task to Standby mode.
Cyclic Task
Execution in Block Execute the selected cyclic task in block. Available only
in Program mode.
Interrupt Task Startup
In Program mode, execute the selected interrupt task
in block. In Monitor/Run mode, an interrupt occurs at
the moment and the process moves to the specified
interrupt task.
Copy
Copy the list of Task Control being displayed to the
clipboard.
Close
Close the Task Control window.
Note
1. Block execution of task sets a start point at the top of the task and a break
point at the bottom (END line), and operates in the same way as Step Run.
2. Refer to
4-4 Task Debugging
for the details of Task Control.
3-9-9 I/O Break Condition Settings Window
I/O Break Condition Setting sets the values of I/O memory with the logical
equation and registers the I/O Break Conditional Equation for breaking at the
step where the set equation holds.
Summary of Contents for CX-Simulator 1.9
Page 1: ...Cat No W366 E1 10 CX Simulator Ver 1 9 SYSMAC WS02 SIMC1 E OPERATION MANUAL...
Page 2: ......
Page 3: ...SYSMAC WS02 SIMC1 E CX Simulator Ver 1 9 Operation Manual Revised December 2009...
Page 24: ...xxv...
Page 30: ...xxxi...
Page 35: ...xxxvi...
Page 39: ......
Page 63: ...Comparison of the CX Simulator and SYSMAC CS CJ series PLCs Section 1 6 24...
Page 75: ...Installing and Uninstalling the Software Section 2 1 36...
Page 157: ...Task Debugging Section 4 4 118...
Page 195: ...Connection with Application Programs Section 7 2 156...
Page 225: ...Checking the Result Section 8 5 186...
Page 277: ...Other Functions Section 9 4 238...
Page 289: ...Other Tips for Troubleshooting Section 10 3 250...
Page 304: ......
Page 305: ......