![background image](http://html1.mh-extra.com/html/omron/cx-simulator-1-9/cx-simulator-1-9_operation-manual_744207297.webp)
How to Use Data Trace Recording Tool
Appendix
258
10. Set options. The following settings are available.
•
Add saving
Add data to the existing file.
•
Multiple Saving Divide and save the data to multiple files when the
number of sampling data exceeds the limit of the
Data Trace file (.cdt).
11. Click the [OK] button when setting options completes to return to the ex-
ecution window.
12. When tracing with the same settings, click the [Add Recording] button to
save the settings to the file (.ini).
13. Click the [Start] button when setting completes to register the setting
contents to the target PLC and to start tracing.
14. While tracing, the elapsed time after the execution started, the number of
tracing samples, and the name of actually saved files (including serial
numbers for multiple saving) will be displayed.
15. Holding of the abort value will automatically stop tracing. Click the [Stop]
button to forcibly stop tracing during execution.
Stating from the Command Line
The [Data Trace Recording Tool] can be started from the command line of the
MS-DOS command prompt, etc. with the setting file (.ini) specified that has
been saved by the [Add Recording] button, as well as from [Start] | [Execute by
Specifying File Name]. If a setting file is specified when starting, the [Data
Trace Recording Tool] will automatically start the data trace.
Follow the next procedure to start from the command line.
Data Record
[< Name of setting file >]
Data Record
Execution command
< Name of setting file >
<Options>
Specify a setting file for saving the traced
data automatically.
If a setting file is specified, tracing will be
started according to the settings.
If not or a non-existing file is specified, the
data trace will not start.
Summary of Contents for CX-Simulator 1.9
Page 1: ...Cat No W366 E1 10 CX Simulator Ver 1 9 SYSMAC WS02 SIMC1 E OPERATION MANUAL...
Page 2: ......
Page 3: ...SYSMAC WS02 SIMC1 E CX Simulator Ver 1 9 Operation Manual Revised December 2009...
Page 24: ...xxv...
Page 30: ...xxxi...
Page 35: ...xxxvi...
Page 39: ......
Page 63: ...Comparison of the CX Simulator and SYSMAC CS CJ series PLCs Section 1 6 24...
Page 75: ...Installing and Uninstalling the Software Section 2 1 36...
Page 157: ...Task Debugging Section 4 4 118...
Page 195: ...Connection with Application Programs Section 7 2 156...
Page 225: ...Checking the Result Section 8 5 186...
Page 277: ...Other Functions Section 9 4 238...
Page 289: ...Other Tips for Troubleshooting Section 10 3 250...
Page 304: ......
Page 305: ......