manualshive.com logo in svg
background image

NetView Service Point

on

SmartSwitch 1800, FRX4000, 

FRX6000, and Frame Relay Module

Supplemental Software

User Guide

09-41-06-092-03

 

The Com plete Network ing Solution

TM

Содержание SmartSwitch 1800

Страница 1: ...NetView Service Point on SmartSwitch 1800 FRX4000 FRX6000 and Frame Relay Module Supplemental Software User Guide 09 41 06 092 03 The Complete Networking Solution T M...

Страница 2: ......

Страница 3: ...d In no event shall the regents or contributors be liable for any direct indirect incidental special exem plary or consequential damages including but notlimitedto procurement of substitutegoods or se...

Страница 4: ...iv NetView Service Point...

Страница 5: ...ly recommended that the software be installed by someone familiar with NetView To install the Cabletron software into the host device follow this procedure 1 Upload the binary EBCDIC files all files w...

Страница 6: ...ion keys listed below will perform the appropriate operation PF1 Help will display a road map of the panels screens shown in Figure 2 PF3 End will exit to the NCCF NetView Controls Command Facility PF...

Страница 7: ...el Figure 3 Line Status Panel PU Status Panel Hardware Config Panel PD Stats Main Status Panel RT and SYS LOGs Frame Relay FR Config PU Config Line Status Panel Line Stats Line Config Service Point BD...

Страница 8: ...urrent states On Off of the modem signals on the line Function Key Operations Pressing one of the function keys listed below will perform the appropriate operation from the Line Status panel PF1 Help...

Страница 9: ...art of the software that is shared with Netlink s SDLC Link Server MAC Address is the Local MAC Address configuredon the LLC2 Parameters screen of the SNA Port record XID is the ID created from IDBLK...

Страница 10: ...ide or a VARY INACT or VARY ACT is sent from the NetVIEW manager NRZI is the inverse of the parameter NRZ in the SNA Port record in the Cabletron device The setting determines the level of data encodi...

Страница 11: ...alent to the Cabletron device parameter No Data Poll Period which is the time between polls by the Cabletron device TPAD of its PU when the PU has no data to send Valid values are 0 125 milliseconds R...

Страница 12: ...manager MAXDATA is equivalent to the Cabletron device parameter Maximum Bytes per Frame Valid values are 25 4105 REPLYTO is equivalent to the Cabletron device parameter No Resp Poll Period whichis the...

Страница 13: ...uired acknowledgment or response from the remote link station The valid values are 0 250 x 100 milliseconds The link station will start the timer when it transmits one of these an Information LPDU a C...

Страница 14: ...P bit set to B 1 to solicit the remote station s status Recovery then proceeds as described under T1 earlier LANIN N3 is the number of Information LPDUs that will be received before sending an acknowl...

Страница 15: ...low will perform the appropriate operation from the PU Status panel PF1 Help will display the Help panel Figure 2 PF2 Exit will return you to the PU Status panel Figure 4 PF3 End will ask whether you...

Страница 16: ...rre sponding event number that is used in this appendix Alert ID Number Event Number Alert ID Number Event Number X 0396D7BA 718 X 6279ADDE 721 X 0AECC2A6 713 X 6E0781DD 717 X 0E2DDF11 712 X 7F15E253...

Страница 17: ...4 X 3511 X F017 SDLC communications remote node Line Poll count exhausted Actions Sender specific actions Additional SVs X 52 SV X 02 SF X 04 SF X 06 SF X 07 SF X 8C SV X 01 SF X 02 SF X 03 SF X 04 SF...

Страница 18: ...tions Sender specific actions Additional SVs X 52 SV X 02 SF X 04 SF X 06 SF X 07 SF X 8C SV X 01 SF X 02 SF X 03 SF X 04 SF X 05 SF X 06 SF X 07 SF X 08 SF X 05 SV X 10 SF LCS Configuration Remote De...

Страница 19: ...0 X F010 Software program Frame reject received invalid unsupported command or response sent Actions Sender specific actions Additional SVs X 52 SV X 02 SF X 04 SF X 06 SF X 07 SF X 8C SV X 01 SF X 02...

Страница 20: ...X F011 Software program Frame reject received i field sent when not permitted Actions Sender specific actions Additional SVs X 52 SV X 02 SF X 04 SF X 06 SF X 07 SF X 8C SV X 01 SF X 02 SF X 03 SF X 0...

Страница 21: ...012 Software program Frame reject received invalid N r sent Actions Sender specific actions Additional SVs X 52 SV X 02 SF X 04 SF X 06 SF X 07 SF X 8C SV X 01 SF X 02 SF X 03 SF X 04 SF X 05 SF X 06...

Страница 22: ...oftware program Frame reject received Maximum I field length exceeded Actions Sender specific actions Additional SVs X 52 SV X 02 SF X 04 SF X 06 SF X 07 SF X 8C SV X 01 SF X 02 SF X 03 SF X 04 SF X 0...

Страница 23: ...s program in remote node Invalid unsupported command or response received Actions Sender specific actions Additional SVs X 52 SV X 02 SF X 04 SF X 06 SF X 07 SF X 8C SV X 01 SF X 02 SF X 03 SF X 04 SF...

Страница 24: ...program in remote node I field received when not permitted Actions Sender specific actions Additional SVs X 52 SV X 02 SF X 04 SF X 06 SF X 07 SF X 8C SV X 01 SF X 02 SF X 03 SF X 04 SF X 05 SF X 06 S...

Страница 25: ...ram in remote node Invalid N r received Actions Sender specific actions Additional SVs X 52 SV X 02 SF X 04 SF X 06 SF X 07 SF X 8C SV X 01 SF X 02 SF X 03 SF X 04 SF X 05 SF X 06 SF X 07 SF X 08 SF X...

Страница 26: ...01B Communications program in remote node Receive window size exceeded Actions Sender specific actions Additional SVs X 52 SV X 02 SF X 04 SF X 06 SF X 07 SF X 8C SV X 01 SF X 02 SF X 03 SF X 04 SF X...

Страница 27: ...LC communications remote node Line Inactivity Timer expired Actions Sender specific actions Additional SVs X 52 SV X 02 SF X 04 SF X 06 SF X 07 SF X 8C SV X 01 SF X 02 SF X 03 SF X 04 SF X 05 SF X 06...

Страница 28: ...Line User Causes X 0209 Remote device power off Actions X 0200 Check power Install Causes none Failure Causes X 2104 X 3511 X F018 SDLC communications remote node Line XID poll count exhausted Action...

Страница 29: ...am Frame reject received no reason specified Actions Sender specific actions Additional SVs X 52 SV X 02 SF X 04 SF X 06 SF X 07 SF X 8C SV X 01 SF X 02 SF X 03 SF X 04 SF X 05 SF X 06 SF X 07 SF X 08...

Страница 30: ...X 1000 X F023 Software program Received I field exceeded maximum length Actions Sender specific actions Additional SVs X 8C SV X 01 SF X 02 SF X 03 SF X 04 SF X 05 SF X 06 SF X 07 SF X 08 SF X 05 SV...

Страница 31: ...ommunications program in remote node Actions X 32A0 Report the following Protocol Error Secondary sent UA in NRM Additional SVs X 8C SV X 01 SF X 02 SF X 03 SF X 04 SF X 05 SF X 06 SF X 07 SF X 08 SF...

Страница 32: ...Resource Name LINE NAME Resource Type X 3D LINE Second resource below sender Resource Name Physical Unit Name Resource Type X 80 Physical Unit Event Log Message linename SDLC No CTS on link Host Conso...

Страница 33: ...ert Description X 3612 No external clock Probable Causes X 2031 X 32D1 Line Local DCE equipment User Causes none Install Causes none Failure Causes X 3601 X 3511 Local modem Link Additional SVs X 05 S...

Страница 34: ...ble for this LAN Report the following Adapter Number Reference Code Additional SVs X 51 SV X 02 SF X 03 SF X 23 SF X 04 SF X 24 SF X 05 SF X 52 SV X 02 SF X 04 SF X 8C SV X 01 SF X 02 SF X 03 SF X 04...

Страница 35: ...llowing Adapter Number Reference Code Additional SVs X 51 SV X 02 SF X 03 SF X 23 SF X 04 SF X 24 SF X 05 SF X 52 SV X 02 SF X 04 SF X 8C SV X 01 SF X 02 SF X 03 SF X 04 SF X 05 SF X 06 SF X 07 SF X 0...

Страница 36: ...ta Contact LAN administrator responsible for this LAN Report the following Adapter Number Reference Code Additional SVs X 51 SV X 02 SF X 03 SF X 23 SF X 04 SF X 24 SF X 05 SF X 52 SV X 02 SF X 04 SF...

Страница 37: ...ng Review link detail data Contact LAN administrator responsible for this LAN Report the following Adapter Number Reference Code Additional SVs X 51 SV X 02 SF X 03 SF X 23 SF X 04 SF X 24 SF X 05 SF...

Страница 38: ...data Contact LAN administrator responsible for this LAN Report the following Adapter Number Reference Code Additional SVs X 51 SV X 02 SF X 03 SF X 23 SF X 04 SF X 24 SF X 05 SF X 52 SV X 02 SF X 04...

Страница 39: ...administrator responsible for this LAN Report the following Adapter Number Reference Code Additional SVs X 51 SV X 02 SF X 03 SF X 23 SF X 04 SF X 24 SF X 05 SF X 52 SV X 02 SF X 04 SF X 8C SV X 01 SF...

Страница 40: ...ontact LAN administrator responsible for this LAN Report the following Adapter Number Reference Code Additional SVs X 51 SV X 02 SF X 03 SF X 23 SF X 04 SF X 24 SF X 05 SF X 52 SV X 02 SF X 04 SF X 8C...

Страница 41: ...the following Review link detail data Contact LAN administrator responsible for this LAN Report the following Adapter Number Reference Code Additional SVs X 51 SV X 02 SF X 03 SF X 23 SF X 04 SF X 24...

Страница 42: ...ew link detail data Contact LAN administrator responsible for this LAN Report the following Adapter Number Reference Code Additional SVs X 51 SV X 02 SF X 03 SF X 23 SF X 04 SF X 24 SF X 05 SF X 52 SV...

Страница 43: ...ntact LAN administrator responsible for this LAN Report the following Adapter Number Reference Code Additional SVs X 51 SV X 02 SF X 03 SF X 23 SF X 04 SF X 24 SF X 05 SF X 52 SV X 02 SF X 04 SF X 8C...

Страница 44: ...following Review link detail data Contact LAN administrator responsible for this LAN Report the following Adapter Number Reference Code Additional SVs X 05 SV X 10 SF Hierarchy Resource List Hierarch...

Страница 45: ...SF X 8C SV X 01 SF X 02 SF X 03 SF X 04 SF X 05 SF X 06 SF X 07 SF X 08 SF X 05 SV X 10 SF LAN LCS Data Ring Segment Identifier Local Individual MAC Address Local Individual MAC Name optional Remote...

Страница 46: ...l transmit error detected The line is shutdown and is retried later Alert ID Number X 32E516A1 Alert Type X 01 Permanent Alert Description X 3300 Link error Probable Causes X 2031 X 2004 Line SDLC com...

Страница 47: ...eceived S or U format frame containing unexpected data received Actions Sender specific actions Additional SVs X 52 SV X 02 SF X 04 SF X 06 SF X 07 SF X 8C SV X 01 SF X 02 SF X 03 SF X 04 SF X 05 SF X...

Страница 48: ......

Отзывы: