10-3-1 Connection Impossible from CX-Programmer
The CX-Simulator is disconnected.
Connect to the CX-Simulator.
Connection to the CX-Simulator does not end normally.
Duplicate FINS address?
Check the FINS addresses for each unit in the [Network Communications
Settings] and that for the communications unit of FinsGateway displayed in the
[Work CX-Simulator] window to dissolve the duplication.
The network LED for the system status does not change in color al-
though the connection to the CX-Simulator ended normally.
In the following cases, communications may be disabled.
•
The other communications unit of FinsGateway was started after connecting
the CX-Simulator.
•
Read a Parameter Area File (.std) to the Ladder Engine.
•
Changed the routing table by the CX-Integrator.
In the above cases, once disconnect the CX-Simulator and then connect
again.
PLC connection is impossible although the network LED for the system
status changes in color.
Check the settings of the application (e.g. the CX-Programmer) connected to
the target FINS address displayed in [Guide to Connect] of [Work to
CX-Simulator] is correct. For the CX-Programmer, check the communications
unit for FinsGateway.
When the communications unit for FinsGateway is connected, once discon-
nect and then connect again.
In the following cases, communications may be disabled.
•
Started the other communications unit of FinsGateway after connecting the
CX-Simulator.
•
Read a Parameter Area File (.std) to the Ladder Engine.
•
Changed the routing table by the CX-Integrator.
Summary of Contents for CX-Simulator 1.9
Page 1: ...Cat No W366 E1 10 CX Simulator Ver 1 9 SYSMAC WS02 SIMC1 E OPERATION MANUAL...
Page 2: ......
Page 3: ...SYSMAC WS02 SIMC1 E CX Simulator Ver 1 9 Operation Manual Revised December 2009...
Page 24: ...xxv...
Page 30: ...xxxi...
Page 35: ...xxxvi...
Page 39: ......
Page 63: ...Comparison of the CX Simulator and SYSMAC CS CJ series PLCs Section 1 6 24...
Page 75: ...Installing and Uninstalling the Software Section 2 1 36...
Page 157: ...Task Debugging Section 4 4 118...
Page 195: ...Connection with Application Programs Section 7 2 156...
Page 225: ...Checking the Result Section 8 5 186...
Page 277: ...Other Functions Section 9 4 238...
Page 289: ...Other Tips for Troubleshooting Section 10 3 250...
Page 304: ......
Page 305: ......