![background image](http://html1.mh-extra.com/html/omron/cx-simulator-1-9/cx-simulator-1-9_operation-manual_744207206.webp)
Generating Virtual External Inputs
Section 8-3
167
8-3-3 Data Replay File (CSV-format text file)
The CSV-format text file (Data Replay File (.csv)) created by a commercial
spreadsheet software can be replayed on the Ladder Engine using the Data
Replay Tool. Besides, the execution result of the Ladder Engine can be saved
in the Data Replay file as the values of I/O memory areas.
Note
Refer to
8-4
Running by Virtual External Inputs
for Replay with Data Replay
Tool.
File Format of Data Replay File
A Data Replay File is an indefinite-length CSV-format text file containing a
parameter line (1st line) and data lines (2nd line and after).
Creator's ID, Data category, I/O address 1, I/O address 2, …, I/O address n <CR><LF>
Date and time, Cycle counter, Value 1, Value 2, …, Value n <CR><LF>
.
.
.
No
Name
The number of
characters
Remarks
1 Creator's ID
Indefinite length File creator's ID (possible to omit,
usually a program name to be saved)
2 Data category 2 or 3
IN/OUT: Input to PLC (IN) or output
from PLC (OUT)
3 I/O address
Indefinite length I/O memory address for input/output
(167 data max.)
4 Date and time 19
YYYY/MM/DD HH:MM:SS (Date and
time of computer, possible to omit)
5 Cycle counter Indefinite length Cycle counter Value when
send/receive
6 Value
Indefinite length The memory value of the specified I/O
memory address (decimal data or
hexadecimal data starting with 0x)
Area Type and Address Range of Usable I/O Memory Area
The following I/O memory areas can be specified by the Data Replay File.
Bit
Area name
Area type
Address range
I/O Area (CIO)
IO
0.00 to 6143.15
Work Area (WR)
W
0.00 to 511.15
Hold Area (HR)
H
0.00 to 511.15
Auxiliary Area (AR)
A
0.00 to 959.15
Summary of Contents for CX-Simulator 1.9
Page 1: ...Cat No W366 E1 10 CX Simulator Ver 1 9 SYSMAC WS02 SIMC1 E OPERATION MANUAL...
Page 2: ......
Page 3: ...SYSMAC WS02 SIMC1 E CX Simulator Ver 1 9 Operation Manual Revised December 2009...
Page 24: ...xxv...
Page 30: ...xxxi...
Page 35: ...xxxvi...
Page 39: ......
Page 63: ...Comparison of the CX Simulator and SYSMAC CS CJ series PLCs Section 1 6 24...
Page 75: ...Installing and Uninstalling the Software Section 2 1 36...
Page 157: ...Task Debugging Section 4 4 118...
Page 195: ...Connection with Application Programs Section 7 2 156...
Page 225: ...Checking the Result Section 8 5 186...
Page 277: ...Other Functions Section 9 4 238...
Page 289: ...Other Tips for Troubleshooting Section 10 3 250...
Page 304: ......
Page 305: ......