![background image](http://html1.mh-extra.com/html/omron/cx-simulator-1-9/cx-simulator-1-9_operation-manual_744207186.webp)
Available FINS Commands
Section 6-5
147
6-5 Available FINS Commands
6-5-1 The List of Available FINS Commands
Type Command
code
Name Function
01
01
MEMORY AREA READ
Reads consecutive data from the I/O memory
area.
01
02
MEMORY AREA WRITE
Writes consecutive data to the I/O memory area.
01
03
MEMORY AREA FILL
Fills the specified range of I/O memory with the
same data.
01 04 MULTIPLE
MEMORY
AREA
READ
Reads non-consecutive data from the I/O memory
area.
I/O Memory
Area Ac-
cess
01
05
MEMORY AREA TRANSFER
Copies and transfers consecutive data from one
part of the I/O memory area to another.
02 01 PARAMETER
AREA
READ Reads consecutive data from the parameter area.
02
02
PARAMETER AREA WRITE
Writes consecutive data to the parameter area.
Parameter
Area Ac-
cess
02
03
PARAMETER AREA FILL
Fills the specified range of the parameter area
with the same data.
03
06
PROGRAM AREA READ
Reads data from the user program area.
03
07
PROGRAM AREA WRITE
Writes data to the user program area.
Program
Area Ac-
cess
03
08
PROGRAM AREA CLEAR
Clears the specified range of the user program
area.
04
01
RUN
Switches the CPU Unit to RUN, MONITOR, or
DEBUG mode.
Execution
Control
04
02
STOP
Switches the CPU Unit to PROGRAM mode.
05 01 CONTROLLER
DATA
READ Reads CPU Unit information.
Configura-
tion Read
05
02
CONNECTION DATA READ
Reads the model numbers of the specified Units.
06
01
CONTROLLER STATUS READ Reads the CPU Unit’s status information.
Status
Read
06
20
CYCLE TIME READ
Reads the average, maximum, and minimum
cycle times.
07
01
CLOCK READ
Reads the clock.
Clock Ac-
cess
07
02
CLOCK WRITE
Sets the clock.
Message
Access
09 20 MESSAGE
READ/CLEAR
Reads/Clears messages and FAL(S) messages.
0C
01
ACCESS RIGHT ACQUIRE
Acquires the access right if no other device holds
it.
0C
02
ACCESS RIGHT FORCED
ACQUIRE
Acquires the access right even if another device
currently holds it.
Access
Right
0C
03
ACCESS RIGHT RELEASE
Releases the access right regardless of what
device holds it.
21
01
ERROR CLEAR
Clears errors and error messages.
21
02
ERROR LOG READ
Reads the error log.
Error Ac-
cess
21
03
ERROR LOG CLEAR
Clears the error log pointer to zero.
22
01
FILE NAME READ
Reads the file memory’s file information.
22
02
SINGLE FILE READ
Reads the specified amount of data from the
specified point in a file.
22
03
SINGLE FILE WRITE
Writes the specified amount of data from the
specified point in a file.
22
04
FILE MEMORY FORMAT
Formats file memory.
22
05
FILE DELETE
Deletes the specified files from file memory.
22
07
FILE COPY
Copies a file within file memory or between two file
memory devices in a system.
File
Memory
22
08
FILE NAME CHANGE
Changes a file name.
Summary of Contents for CX-Simulator 1.9
Page 1: ...Cat No W366 E1 10 CX Simulator Ver 1 9 SYSMAC WS02 SIMC1 E OPERATION MANUAL...
Page 2: ......
Page 3: ...SYSMAC WS02 SIMC1 E CX Simulator Ver 1 9 Operation Manual Revised December 2009...
Page 24: ...xxv...
Page 30: ...xxxi...
Page 35: ...xxxvi...
Page 39: ......
Page 63: ...Comparison of the CX Simulator and SYSMAC CS CJ series PLCs Section 1 6 24...
Page 75: ...Installing and Uninstalling the Software Section 2 1 36...
Page 157: ...Task Debugging Section 4 4 118...
Page 195: ...Connection with Application Programs Section 7 2 156...
Page 225: ...Checking the Result Section 8 5 186...
Page 277: ...Other Functions Section 9 4 238...
Page 289: ...Other Tips for Troubleshooting Section 10 3 250...
Page 304: ......