Generating Virtual External Inputs
Section 8-3
165
Read IOM area
MR
SR
PM
FINS Command
Replay possible
01
01
30
Read CIO Area bits
Not possible
01
01
31
Read Work Area bits
Not possible
01
01
32
Read Hold Area bits
Not possible
01
01
33
Read Auxiliary Area bits
Not possible
01
01
B0
Read CIO Area words
Not possible
01
01
B1
Read Work Area words
Not possible
01
01
B2
Read Hold Area words
Not possible
01
01
B3
Read Auxiliary Area words
Not possible
01
01
09
Read Timer/Counter Completion Flag Not possible
01 01 89 Read
Timer/Counter
PV
Not
possible
01 01 02 Read
DM
bits
Not
possible
01 01 82 Read
DM
words
Not
possible
01
01
2
Read EM bits (common)
Not possible
01
01
A
Read EM words (common)
Not possible
01
01
98
Read EM words (current bank)
Not possible
01
01
BC
Current EM Bank No.
Not possible
01
01
06
Read task flag bit
Not possible
01
01
46
Read task flag status
Not possible
01
01
DC
Read Index Register PV
Not possible
01
01
BC
Read Data Register PV
Not possible
01 01 07 Read
Clock/Condition
bit
Not
possible
Write IOM area
MR
SR
PM
FINS Command
Replay possible
01 02 30 Write
CIO
Area
bits
Possible
01 02 31 Write
Work
Area
bits
Possible
01 02 32 Write
Hold
Area
bits
Possible
01 02 33 Write
Auxiliary
Area
bits
Possible
01
02
B0
Write CIO Area words
Possible
01
02
B1
Write Work Area words
Possible
01
02
B2
Write Hold Area words
Possible
01
02
B3
Write Auxiliary Area words
Possible
01 02 89 Write
Timer/Counter
PV
Possible
01 02 02 Write
DM
bits
Possible
01 02 82 Write
DM
words
Possible
01
02
2
Write EM bits (common)
Possible
01
02
A
Write EM words (common)
Possible
01
02
98
Write EM words (current bank)
Possible
01
02
BC
Current EM Bank No.
Possible
01
02
DC
Write Index Register PV
Possible
01
02
BC
Write Data Register PV
Possible
MR: Main, SR: Sub, PM: Parameter
Note
If Replay is not possible, the I/O memory areas do not change although
send/receive of data is executed when Replay.
Summary of Contents for CX-Simulator 1.9
Page 1: ...Cat No W366 E1 10 CX Simulator Ver 1 9 SYSMAC WS02 SIMC1 E OPERATION MANUAL...
Page 2: ......
Page 3: ...SYSMAC WS02 SIMC1 E CX Simulator Ver 1 9 Operation Manual Revised December 2009...
Page 24: ...xxv...
Page 30: ...xxxi...
Page 35: ...xxxvi...
Page 39: ......
Page 63: ...Comparison of the CX Simulator and SYSMAC CS CJ series PLCs Section 1 6 24...
Page 75: ...Installing and Uninstalling the Software Section 2 1 36...
Page 157: ...Task Debugging Section 4 4 118...
Page 195: ...Connection with Application Programs Section 7 2 156...
Page 225: ...Checking the Result Section 8 5 186...
Page 277: ...Other Functions Section 9 4 238...
Page 289: ...Other Tips for Troubleshooting Section 10 3 250...