Communications Settings for Serial Communications
Communications Settings
for Serial Communications
When using serial communications instructions in a program, communications
settings for each port number to be used can be specified. Serial communica-
tions settings include the following settings.
Communications
Settings
Contents
−
Communications are not processed.
Messages
Display the contents of messages that would be sent to
an external device. (Actually messages are not sent.)
File
Write communications data to a file and read from the
file.
Actual communica-
tions
Possible to communicate in Host Link (SYSMAC WAY),
NT Link, or No-protocol via a COM port on the computer.
Operations of Auxiliary Area
The table below shows differences in operation of Status Area and Auxiliary
Area when set as communications are not actually performed (“-“/”Messages”).
Instruction Contents
TXD
RS-232C Port Send Ready Flag
Always ON
RS-232C Port Reception Completed Flag
Always OFF
RS-232C Port Reception Overflow
Flag
Always OFF (No
error)
RXD
RS-232C Port Reception Counter
Always 0
STUP
RS-232C Port Settings Changing
Flag
Always OFF
Network Communications Error Flag
Always OFF (No
error)
Network Communications Enabled Flag
Disabled (OFF) at
command issue and
enabled (ON) at
peripheral servicing
in the same cycle.
Network instruc-
tions
SEND/RECV
/CMND
Network Communications Completion
Code
Cleared (always
normal status)
Save communications history to a file when serial communications are per-
formed with a COM port on the computer allocated. This function is available
when the communications setting for serial communications is set to “File” or
“Actual communications,” although disabled for NT Link.
COM Port Logging Function
•
Folder
PLC data folder\LOG
•
Input file name
COM port name LOG.txt
Error Logs
The error logs function of Serial Communications Boards/Unit is not available.
Summary of Contents for CX-Simulator 1.9
Page 1: ...Cat No W366 E1 10 CX Simulator Ver 1 9 SYSMAC WS02 SIMC1 E OPERATION MANUAL...
Page 2: ......
Page 3: ...SYSMAC WS02 SIMC1 E CX Simulator Ver 1 9 Operation Manual Revised December 2009...
Page 24: ...xxv...
Page 30: ...xxxi...
Page 35: ...xxxvi...
Page 39: ......
Page 63: ...Comparison of the CX Simulator and SYSMAC CS CJ series PLCs Section 1 6 24...
Page 75: ...Installing and Uninstalling the Software Section 2 1 36...
Page 157: ...Task Debugging Section 4 4 118...
Page 195: ...Connection with Application Programs Section 7 2 156...
Page 225: ...Checking the Result Section 8 5 186...
Page 277: ...Other Functions Section 9 4 238...
Page 289: ...Other Tips for Troubleshooting Section 10 3 250...
Page 304: ......
Page 305: ......