![background image](http://html1.mh-extra.com/html/omron/cx-simulator-1-9/cx-simulator-1-9_operation-manual_744207292.webp)
How to Use Data Trace Recording Tool
Appendix
253
Explanation for Each Part of the Window
Names and Functions
Item
Description
Limit of values
Target PLC to
Trace
Specify the FINS address for the PLC where data tracing will be
performed.
Only network/node address can be input.
Network: 0 to 127
Node: 1 to 126
Unit: 0(fixed)
Sampling Area
Register addresses where bits and words are sampled.
[Edit]: Edit bit/word addresses in the Sampling Address Setting
window.
Set at least one to either of bits or words within the range on the
right.
Number of bits: 0 to 31
Number of words: 0 to 6
Sampling interval
Set the sampling conditions with the radio button.
Interval
Set the sampling interval as "fixed" and enter the interval in the
text box (unit: ms).
10 to 2550
Per cycle
Trace per cycle of the ladder program.
Abort Value
Specify the value for exiting the data tracing.
Type
Specify either of after getting specified number of samples or
after specified time elapsed.
Samples
Specify the value for exiting the data tracing.
1 to 65535
Trace
elapsed
Specify the time for tracing.
1 to 65535
Unit
Specify the unit for the time above: either of second, minute, or
hour.
Trace Data Record
File
Specify the file name for saving the sampling data: either in a
relative path or in an absolute path.
A network name can not
be specified.
Browse
Display the File Name Setting dialog.
Options settings Set options regarding trace data saving.
Target PLC to
Trace
Sampling
interval
Trace Data
Record file
Trace Status
Write settings
button
Read settings
button
Sampling Area
Abort Value
Start button
Exit button
Options button
Summary of Contents for CX-Simulator 1.9
Page 1: ...Cat No W366 E1 10 CX Simulator Ver 1 9 SYSMAC WS02 SIMC1 E OPERATION MANUAL...
Page 2: ......
Page 3: ...SYSMAC WS02 SIMC1 E CX Simulator Ver 1 9 Operation Manual Revised December 2009...
Page 24: ...xxv...
Page 30: ...xxxi...
Page 35: ...xxxvi...
Page 39: ......
Page 63: ...Comparison of the CX Simulator and SYSMAC CS CJ series PLCs Section 1 6 24...
Page 75: ...Installing and Uninstalling the Software Section 2 1 36...
Page 157: ...Task Debugging Section 4 4 118...
Page 195: ...Connection with Application Programs Section 7 2 156...
Page 225: ...Checking the Result Section 8 5 186...
Page 277: ...Other Functions Section 9 4 238...
Page 289: ...Other Tips for Troubleshooting Section 10 3 250...
Page 304: ......
Page 305: ......