Running by Virtual External Inputs
Section 8-4
182
essing is performed asynchronously with the PLC scan. As a result, data
may be lost if I/O status changes too quickly. If synchronized processing is
used, data will not be lost, but processing will be slowed down by the
amount of time required to synchronize.
5. After checking the settings, click the [Start] button.
Pausing the I/O Condition
Tool
The I/O Condition Tool pauses in the following conditions of the Ladder En-
gine.
Conditions of the
Ladder Engine
Synchronous/Asynchronous
How to clear
Program/Run mode
Synchronous/Asynchronous
Scan Run for Synchronous
and Continuous Run (Monitor
mode) for Asynchronous.
Step Run, or Pause in
the Debug Console
Synchronous Scan
Run
Break on Break Points Synchronous Scan
Run
Break on I/O Break
Condition
Synchronous Scan
Run
Note
When the computer cycle time is 10 ms or more, hold of conditions may fail to
be caught. In this case, use in the virtual cycle time.
Note
Do not perform Continuous Run (in the Monitor mode) or Continuous Scan
Run while synchronizing the I/O Condition Tool. Doing so will lose synchro-
nism in the unit of a scan. When the program has been interrupted on a break
point, etc., resume it with Scan Run.
Note
While executing asynchronously, the I/O memory areas are monitored even
while the Ladder Engine is not executing a ladder program due to break, etc.
8-4-4 How to Replay Using the Program Area for Debugging
This section explains how to perform virtual external input (download and
execute) using the program area for debugging.
1,2,3…
1. Press the [Settings] button in the [System Status Settings] dialog box, and
then select [UM Settings] to display the [UM Settings] window.
Summary of Contents for CX-Simulator 1.9
Page 1: ...Cat No W366 E1 10 CX Simulator Ver 1 9 SYSMAC WS02 SIMC1 E OPERATION MANUAL...
Page 2: ......
Page 3: ...SYSMAC WS02 SIMC1 E CX Simulator Ver 1 9 Operation Manual Revised December 2009...
Page 24: ...xxv...
Page 30: ...xxxi...
Page 35: ...xxxvi...
Page 39: ......
Page 63: ...Comparison of the CX Simulator and SYSMAC CS CJ series PLCs Section 1 6 24...
Page 75: ...Installing and Uninstalling the Software Section 2 1 36...
Page 157: ...Task Debugging Section 4 4 118...
Page 195: ...Connection with Application Programs Section 7 2 156...
Page 225: ...Checking the Result Section 8 5 186...
Page 277: ...Other Functions Section 9 4 238...
Page 289: ...Other Tips for Troubleshooting Section 10 3 250...
Page 304: ......
Page 305: ......