Outline of Operation Procedure
Section
3-4
47
10. Monitor/ Debug
10-1 Monitor
Monitor I/O bit status and PV.
Execute force-set/reset, trace, online edit, and others.
10-2 Program Check by Break
Set break points and I/O break conditions in the ladder diagram as
required and stop the program step by step to monitor the contents of
I/O memory.
Refer to
4-3 Step Run and Break
.
10-3 Cycle Time Monitor
Confirm the virtual cycle time so that the program execution time on
the actual PLC is within the permissible range.
10-4 Task Operation Check
Check the number and time of the task execution in the [Task Con-
trol] window. If an interrupt task exists, execute the program with the
interrupt timing changed to check the interrupt operation.
Refer to
4-4 Task Debugging
.
10-5 Serial/ Network Communications
Display the contents of serial/network communications to debug with
actual communications.
Refer to
5 Debugging Serial Communications
and
6 Debugging Network Communications.
11. Debugging by Virtual External Inputs
11-1 Generating Virtual External Inputs
Create data/program for virtual external inputs.
Refer to
8-3 Generating Virtual External Inputs
.
11-2 Virtual Run
Generate virtual external inputs using the created data/program to
virtually run the ladder diagram in more actual way.
Refer to
8-4 Running by Virtual External Inputs
.
11-3 Check Results
Check the results of the virtual run by the time chart monitor or
spreadsheet software.
Refer to
8-5 Checking the Result
12. Switching to the actual PLC
Disconnect the Simulator and check the program again with the actual
PLC connected.
Summary of Contents for CX-Simulator 1.9
Page 1: ...Cat No W366 E1 10 CX Simulator Ver 1 9 SYSMAC WS02 SIMC1 E OPERATION MANUAL...
Page 2: ......
Page 3: ...SYSMAC WS02 SIMC1 E CX Simulator Ver 1 9 Operation Manual Revised December 2009...
Page 24: ...xxv...
Page 30: ...xxxi...
Page 35: ...xxxvi...
Page 39: ......
Page 63: ...Comparison of the CX Simulator and SYSMAC CS CJ series PLCs Section 1 6 24...
Page 75: ...Installing and Uninstalling the Software Section 2 1 36...
Page 157: ...Task Debugging Section 4 4 118...
Page 195: ...Connection with Application Programs Section 7 2 156...
Page 225: ...Checking the Result Section 8 5 186...
Page 277: ...Other Functions Section 9 4 238...
Page 289: ...Other Tips for Troubleshooting Section 10 3 250...
Page 304: ......
Page 305: ......