Comparison of the CX-Simulator and SYSMAC CS/CJ-series PLCs
Section 1-6
21
Item CS/CJ-series
PLC
CX-Simulator
Sequence Input
Equivalent
Sequence Output
Equivalent
Sequence Control
Equivalent
Equivalent (The MILH and MILR
instructions, however, cannot be
used to control the ON/OFF status
of interlocks by forcing ON/OFF
the bit specified for the second
operand. The interlocks must be
controlled through the execution
condition of the instruction.)
Timer/Counter
Equivalent (TRSET is equivalent only for CJ2-series PLCs.)
Comparison Equivalent
Data Movement
Equivalent
Data Shift
Equivalent
Increment/Decrement Equivalent
Symbol Math
Equivalent
Conversion Equivalent
(GRAY_BIN,
GRAY_BINL, BIN_GRAY, BIN_GRAYL are
equivalent only for CJ2-series PLCs.)
Logic Equivalent
Special Math
Equivalent
Floating-point Math
Equivalent (A rounding error may occur.)
Table Data Processing
Equivalent
Tracking
MAXL, MINL, MAXF, MINF, MAXD, MIND are equivalent only for
CJ2-series PLCs.
Data Control
Equivalent (Nothing is executed for PID.)
Subroutines Equivalent
Interrupt Control
Equivalent
Step Equivalent
Basic I/O Unit
IORF, IORD, IOWR, TKY, HKY,
7SEG, and DSW available.
Nothing is executed for the IORF,
IORD, or IOWR instructions.
Serial Communications
PMCR, and PMCR2 available.
TXD, RXD, and STUP available.
Nothing is executed for PMCR or
PMCR2.
TXD, RXD, and STUP operate
differently depending on commu-
nications parameters.
TXDU2, and RXDU2 operate only
for CJ2-series PLCs.
Network
SEND, RECV, and CMND available.
CSND available.
SEND, RECV, and CMND operate
differently depending on commu-
nications parameters.
Nothing is executed for CSND.
SEND2, RECV2, and CMND2
operate only for CJ2-series PLCs.
File Memory
Equivalent
Display
Equivalent (Messages of Programming Console are displayed on the
screen.)
High-Speed Counter Pulse
Control Instructions (CJ1M
only)
INI, SPED, PRV, PRV2, CTBL,
PULS, ACC, PLS2, ORG, and PWM
instructions
Nothing is executed for the in-
structions listed at the left.
Clock
Equivalent (With the CX-Simulator, however, even if the time in the PLC is
adjusted with the DATE instruction, it will be automatically corrected to the
time in the computer at the end of the cycle in which the DATE instruction is
executed.)
Instructions
Debugging Equivalent
Summary of Contents for CX-Simulator 1.9
Page 1: ...Cat No W366 E1 10 CX Simulator Ver 1 9 SYSMAC WS02 SIMC1 E OPERATION MANUAL...
Page 2: ......
Page 3: ...SYSMAC WS02 SIMC1 E CX Simulator Ver 1 9 Operation Manual Revised December 2009...
Page 24: ...xxv...
Page 30: ...xxxi...
Page 35: ...xxxvi...
Page 39: ......
Page 63: ...Comparison of the CX Simulator and SYSMAC CS CJ series PLCs Section 1 6 24...
Page 75: ...Installing and Uninstalling the Software Section 2 1 36...
Page 157: ...Task Debugging Section 4 4 118...
Page 195: ...Connection with Application Programs Section 7 2 156...
Page 225: ...Checking the Result Section 8 5 186...
Page 277: ...Other Functions Section 9 4 238...
Page 289: ...Other Tips for Troubleshooting Section 10 3 250...
Page 304: ......
Page 305: ......