![background image](http://html1.mh-extra.com/html/omron/cx-simulator-1-9/cx-simulator-1-9_operation-manual_744207006.webp)
vii
Simplified System Exit Processing
When the system is exited while the CX-Simulator is connected, a confirma-
tion dialog box will appear and, upon confirmation, the CX-Simulator will be
disconnected and the system shut down.
Version 1.3
The following functions have been added to the CX-Simulator with the upgrade from Version 1.2 to
Version 1.3.
New PLCs Supported
Simulation is newly supported for the following PLCs.
Series
CPU Unit model numbers
CJ CJ1M-CPU23/22/13/12
New Units in the CS and CJ Series are also supported for PLC Unit registra-
tion.
Starting and Connecting the CX-Simulator from the CX-Programmer
With CX-Programmer version 3.0 or higher, the CX-Simulator can be started
and connected (placed online) from the CX-Programmer. After going online,
program transfer to the CX-Simulator can be started immediately.
Windows XP Supported
Version 1.4
The following functions have been added to the CX-Simulator with the upgrade from Version 1.3 to
Version 1.4.
New PLCs Supported
Simulation is newly supported for the following PLCs.
Series
CPU Unit model numbers
CS CS1D-CPU67H/65H
CS1D-CPU67S/65S/44S/42S
CJ CJ1M-CPU23/22/21/13/12/11
New Units in the CS and CJ Series are also supported for PLC Unit registra-
tion.
Version 1.5
The changes that have been made from version 1.4 to version 1.5 of the CX-Simulator to enable support of new
CPU Unit models are explained here.
New PLCs Supported
CX-Simulator version 1.5 supports the following new CPU Units.
Series
CPU Unit model
CS CJ1H-CPU67H
CPU Unit Version Upgrade Compatibility
CX-Simulator version 1.5 supports the following CS/CJ-series CPU Units with
unit version 3.0.
Series Device
type
CS/CJ
CS1G-H, CS1H-H, CJ1G-H, CJ1H-H, CJ1M
Summary of Contents for CX-Simulator 1.9
Page 1: ...Cat No W366 E1 10 CX Simulator Ver 1 9 SYSMAC WS02 SIMC1 E OPERATION MANUAL...
Page 2: ......
Page 3: ...SYSMAC WS02 SIMC1 E CX Simulator Ver 1 9 Operation Manual Revised December 2009...
Page 24: ...xxv...
Page 30: ...xxxi...
Page 35: ...xxxvi...
Page 39: ......
Page 63: ...Comparison of the CX Simulator and SYSMAC CS CJ series PLCs Section 1 6 24...
Page 75: ...Installing and Uninstalling the Software Section 2 1 36...
Page 157: ...Task Debugging Section 4 4 118...
Page 195: ...Connection with Application Programs Section 7 2 156...
Page 225: ...Checking the Result Section 8 5 186...
Page 277: ...Other Functions Section 9 4 238...
Page 289: ...Other Tips for Troubleshooting Section 10 3 250...
Page 304: ......
Page 305: ......