background image

 

Part No. 115385-D Rev 01
December 1998

BayStream Multiservice Software Version 7.3
BayStream Site Manager Version 7.3 

BayStream 7.3
Documentation Change
Notice

Summary of Contents for Baystream 7

Page 1: ...Part No 115385 D Rev 01 December 1998 BayStream Multiservice Software Version 7 3 BayStream Site Manager Version 7 3 BayStream 7 3 Documentation Change Notice ...

Page 2: ...hts of the United States Government regarding its use reproduction and disclosure are as set forth in the Commercial Computer Software Restricted Rights clause at FAR 52 227 19 Statement of Conditions In the interest of improving internal design operational function and or reliability Bay Networks Inc reserves the right to make changes to the products described in this document without notice Bay ...

Page 3: ...otherwise disclose to any third party the Software or any information about the operation design performance or implementation of the Software and user manuals that is confidential to Bay Networks and its licensors however Licensee may grant permission to its consultants subcontractors and agents to use the Software at Licensee s facility provided they have agreed to use the Software only in accor...

Page 4: ...fective at the date of expiration of the Bay Networks copyright those restrictions relating to use and disclosure of Bay Networks confidential information shall continue in effect Licensee may terminate this license at any time The license will automatically terminate if Licensee fails to comply with any of the terms and conditions of the license Upon termination for any reason Licensee will immed...

Page 5: ...terface 6 Using Site Manager 8 Using File Transfer Protocols 10 TFTP 10 FTP 11 Saving Statistics to the VFS 11 Using Site Manager 12 Using the Technician Interface 13 Log Messages 13 Resilient NNI 13 Architecture 14 Features 14 Master Node Operation 15 Slave Node Operation 15 Link Phases 16 Sample Configurations 16 Initialization and Startup Phase 17 LIV Status Enquiry Procedures 18 Fast Start Pro...

Page 6: ...ed 36 Loopback Corrected Normal Condition 37 Enabling Loopback Detection Using Site Manager 37 Enabling Loopback Detection Using the Technician Interface 38 Monitoring Loopback Detection Using the Technician Interface 38 UNI and NNI Traffic Policing Disable 38 Enabling Traffic Policing Using Technician Interface 38 Enabling Traffic Policing Using Site Manager 39 Disable of PVC and SVC Billing 39 U...

Page 7: ... 57 Frame Relay Switch FRSW Events 57 Non Volatile File System NVFS Events 59 Telnet Server Protocol TELNET 59 STATS to DRAM 59 Changes to MIBs 60 The Volatile File System Table 60 Resilient Network to Network Interface 63 The RNNI DLCMI Table 63 The RNNI Configuration CFG Table 85 The Resilient NNI Virtual Circuit Table 88 Data Link Connection Management Interface 116 High Speed Serial Interface ...

Page 8: ......

Page 9: ...ation with HSSI to DS3 Interfaces 17 Figure 7 Displaying the Interfaces 28 Figure 8 Enabling Statistics Collection for an Interface 28 Figure 9 Displaying the Interfaces 41 Figure 10 Enabling Billing Information Collection for PVCs on an Interface 41 Figure 11 Enabling Billing Information Collection for SVCs on an Interface 42 Figure 12 Configuring a Dynamic Port Number 42 Figure 13 Configuring a ...

Page 10: ......

Page 11: ...to Support Version 7 3 3 Table 3 NVFS Commands 7 Table 4 Status Enquiry and Response Messages 18 Table 5 Atmizer Bit Mask 31 Table 6 svcs Field Descriptions 34 Table 7 Technician Interface Commands Used to Enable Test Traffic Generation 50 Table 8 Reallocating Memory 55 Table 9 ATM Bit Mask 120 ...

Page 12: ......

Page 13: ... Example If the command syntax is ping ip_address you enter ping 192 32 10 12 bold text Indicates text that you need to enter and command names and options Example Enter show ip alerts routes Example Use the dinfo command braces Indicate required elements in syntax descriptions where there is more than one option You must choose only one of the options Do not type the braces when entering the comm...

Page 14: ...ames new terms book titles and variables in command syntax descriptions Where a variable is two or more words the words are connected by an underscore Example If the command syntax is show at valid_route valid_route is one variable and you substitute one value for it screen text Indicates system output for example prompts and system messages Example Set Bay Networks Trap Monitor Filters separator ...

Page 15: ...level data link control HSSI High Speed Serial Interface IFTF interframe time fill IP Internet Protocol ISDN Integrated Services Digital Network LAN local area network MIB management interface base MNP Microcom Networking Protocol NNI network to network interface NVRAM nonvolatile random access memory OSPF Open Shortest Path First protocol PPP Point to Point Protocol RAM random access memory SDLC ...

Page 16: ... Bay Networks documentation sets CDs and selected technical publications through the Bay Networks Collateral Catalog The catalog is located on the World Wide Web at support baynetworks com catalog html and is divided into sections arranged alphabetically The CD ROMs section lists available CDs The Guides Books section lists books on technical topics The Technical Manuals section lists available pr...

Page 17: ...tream Version 7 3 changes Table 1 Version 7 3 New Features Section Name Description of Contents Page Volatile File System Describes how to configure and manage the Volatile File System VFS file system for use as a temporary storage device for a BayStream switch 4 Saving Statistics to the VFS Describes how to use the VFS to save statistics 11 Resilient NNI Describes how to configure and manage a Re...

Page 18: ... the show frsw Technician Interface script which displays information on active SVC calls and the duration of these calls 33 FRF 2 1 and FRF 1 1 Loopback Detection Describes how to configure and manage loopback detection to determine the link integrity of a circuit 35 UNI and NNI Traffic Policing Disable Describes how to enable and disable traffic policing on a user to network UNI or NNI interface...

Page 19: ...ce for installing Site Manager 44 Additions to Configuring Line Services Describes the following Setting the Asynchronous Baud Rate parameter Setting the synchronous inter frame time fill IFTF pattern Setting the high speed serial inter face HSSI carrier loss timeout Enabling the Receive All Frame parameter 44 Changes to Configuring IP Services Describes the following Restricting and prioritizing ...

Page 20: ...the FLASH SRAM file system Changes to MIBs Identifies changes to MIBs 60 Change to Configuring Frame Relay Switching Services Modifies the description of the VC ATM FR IW EFCI Policy parameter 122 Change to Configuring Frame Relay to ATM Interworking Presents the following Modified description of the VC ATM FR IW EFCI Policy parameter Modified description of the VCI Number parameter 123 Change to ...

Page 21: ... Notice 115385 D Rev 01 BayStream Multiservice Software Version 7 3 5 VFS supports the same set of Technician Interfacecommands and standard file transfer protocols as FLASH SRAM You can also use Site Manager to configure and manage VFS ...

Page 22: ... 2 Use the set command to specify the size of the volume Figure 2 shows an example of a set command that sets the file size in Slot 1 to 500000 bytes Figure 1 Creating a VFS Volume Figure 2 Setting the Size of a VFS Volume Use the Technician Interface commands shown in Table 3 to manage the VFS volume 4 1 set wfFrSwExtFileSysEntry 1 1 1 BYS0089A TI set command NVFS DRAM file system MIB entry Attri...

Page 23: ... detailed description of how to use Technician Interface commands to manage the VFS Command Function compact Reallocates file space on a memory card cd Changes the active volume copy Copies a file from one volume to another or to the same volume delete Deletes a file from a volume dinfo Displays the volume number status and space for each volume dir Displays all files on a volume format Erases any...

Page 24: ...window choose Platform 2 Choose Volatile File Systems The Volatile File Systems window opens 3 Click on ADD The ADD dialog box opens 4 Enter the number of the slot number where you want to create the Volatile File System and file size 5 Click on OK Site Manager returns you to the VFS Filesystems window The new volume appears in the window 6 Click on DONE Site Manager returns you to the Configurati...

Page 25: ...w opens It contains the IP address of the switch the current file system volume a list of files file sizes the date and time files were last modified and statistics about the size of the volume 3 Select the file system volume that you want to access VFS volumes contain an x after the volume slot number Site Manager displays the list of files contained in the volume you selected 4 Use the features ...

Page 26: ...E FREE SPACE CONTIG FREE SPACE 3x FORMATTED 500000 499966 499966 4 FORMATTED 8388608 2440559 2440559 4x FORMATTED 500000 494376 494376 5x FORMATTED 1500000 1499966 1499966 4 1 tftp put 192 32 51 114 4 config 3x test cfg Transfer with 192 32 52 114 completed successfully 4 1 dir 3x Volume in drive 3x is Directory of 3x File Name Size Date Day Time test cfg 5556 10 11 98 Fri 10 18 32 500000 bytes To...

Page 27: ...ssful 150Image data connection for 3x test 192 32 51 114 20 226Binary Transfer Complete local test remote 3x test 48128 bytes sent in 0 17 seconds 2 7e 02 Kbytes s ftp get 3x test cfg test cfg 200PORT command successful 150Image data connection for 3x test 192 32 51 114 20 5556 bytes 226Binary Transfer Complete local test cfg remote 3x test cfg 5556 bytes sent in 0 46 seconds 12 Kbytes s ftp quit ...

Page 28: ... 2 Choose Statistical Data Collection The Statistical Data Collection window opens 3 Choose Global The Global window opens 4 At the Global window set the following parameters Save to VFS DRAM Enable Enabled Master Volume Number enter the volume number which is the slot number on which you have VFS configured 51 5 Click on OK Site Manager returns you to the Statistical Data Collection window The ne...

Page 29: ...volume is not found the following message would be displayed 2 09 11 1998 16 00 05 300 WARNING SLOT 4 STATS Code 33 Error in mounting 4x No room for STATS file on slot 4 Resilient NNI Resilient NNI network to network interface connects a Bay Networks BayStream switch to frame relay switches of other vendors that support Resilient NNI Resilient NNI provides failure resiliency for NNI links between ...

Page 30: ...figured to operate in the master mode and has ports A1 and A2 on different slots connected to Link 1 and Link 2 respectively Similarly the NNI gateway node belonging to Network B is configured to operate in the slave mode and has ports B1 and B2 on different slots connected to Link 1 and Link 2 respectively Figure 4 Resilient NNI Architecture Features Resilient NNI supports the following features ...

Page 31: ...ference is used to bias the selection of the active link If the preferred link is unable to be initialized this protocol will automatically select and activate the backup link If the backup link is activated traffic will continue to be sent over the backup link until the link fails or network management intervention reverts traffic back to the primary link The slave node does not have administrati...

Page 32: ...ed link has been determined and bi directional procedures have started Sample Configurations Figure 5 and Figure 6 show some sample Resilient NNI configurations using Newbridge and Ascend switches Figure 5 Bay Networks Resilient NNI Configuration with HSSI Interface Only FDDI Ring FDDI Ring BYS0092A Bay Networks Frame Relay HSSI HSSI BNX with HSSI card New standardized BNX Node POP NNI POP B POP C...

Page 33: ...NI protocol uses these messages to indicate PVC status Table 4 contains a description of each type of status enquiry and response message FDDI Ring FDDI Ring BYS0093A Bay Networks Frame Relay HSSI HSSI DS3 DS3 X Connect Other Frame Relay switch with unchannelized DS3 card BNX with HSSI card New standard BNX Node MCI Timing Source MCI Timing Source DS3 DS3 DS3 Digital Link 3100 DSU provides DS3 to ...

Page 34: ...h a full status response and initiates bi directional procedures on that link Table 4 Status Enquiry and Response Messages Message Type Description Link Integrity Verification LIV Status Enquiry Represents a Status Enquiry Message with a Report Type of Link Integrity Verification Only Link Integrity Verification LIV Status Response Represents a Status Message with a Report Type of Link Integrity V...

Page 35: ...us enquiry messages on the selected link for a configurable amount of time If the configurable amount of time expires then the master node assumes that the selected link is unavailable The master node will then attempt to activate the alternate link The amount of time that the master node sends full status enquiry messages on either link will be based on a counter called N_attempt This counter ope...

Page 36: ...dure is one directional The slave node is able to detect and immediately process a Full status enquiry message with a full status response message if the master node switches links from active to backup for example for maintenance purposes Bi directional Annex A procedures are then disabled on the active link and initialized on the backup link The slave node will maintain the current Send and Rece...

Page 37: ...curs The SVC connections may be left in the half connected state This condition is similar to the bouncing of UNI SVC interface on a BayStream software release prior to Revision 7 3 SVC Operation The Annex A link management and selection procedures described in the previous section are used to determine the active link for SVC operation Either the master or slave node can initiate LAPF procedures ...

Page 38: ...roup information is used internally within the BayStream network BayStream does not support transfer or mapping of CUG information across a Resilient NNI interface Libraries and External Interface No libraries or external interfaces are required to configure or manage a Resilient NNI Configuring the Resilient NNI You can use Site Manager or the Technician Interface to configure Resilient NNI Using...

Page 39: ...e default name identifies the circuit type the slot number of the link module and the number of the physical connector on the link module that supports the circuit For example The circuit name H51indicates a HSSI circuit supported by the HSSI link module in slot 5 and the physical connector The WAN Protocol window opens 4 Choose FR Switch The DLCMI Configuration window opens 5 At the DLCMI CONFIGU...

Page 40: ...is System responds 1 Click on one of the HSSI connectors that you want to create a pair of Resilient NNI link The Edit Connector window opens 2 Choose Edit Circuit The Circuit Definition window opens 3 Choose Protocols 4 Choose Edit Frame Relay Switch 5 Choose RNNI 6 Choose Add Site Manager displays a list of available HSSI RNNI ports 7 Choose a HSSI RNNI port 8 Click on Done Site Manager returns ...

Page 41: ... Resilient NNI enabled on slot 4 and slot 5 using circuit number 3 do the following 4 1 set wfHssiEntry wfHssiFrSwRnniEnabled 4 1 1 4 1 set wfHssiEntry wfHssiCct 4 1 3 Site Manager Procedure You do this System responds 1 In the Configuration Manager window choose Protocols 2 Choose Frame Relay Switch 3 Choose RNNI Global 4 Choose one of the Resilient NNI links The Edit Connector window opens 5 Cho...

Page 42: ...705101 1 4 1 set wfFrSwRnniCfgEntry wfFrSwRnniCfgPeerLineNumber 705101 704101 4 1 set wfFrSwRnniCfgEntry wfFrSwRnniCfgDlcmiCct 705101 3 One wfFrSwDlcmiEntry instance indexed by the same circuit number of wfHssiCct Attribute wfFrSwDlcmiNniEnable must be enabled wfFrSwDlc miManagementType must be Annex A Switch and wfFrSwDlcmiBidirect must be enabled For example to set the link management parameter ...

Page 43: ...h as shown in Figure 7 2 Use the Technician Interface set command to enable the collection of statistics for one of the interfaces in Step 1 Figure 8 shows an example of a set command which enables statistics for SVCs on an interface Site Manager Procedure You do this System responds 1 In the Configuration Manager window choose Protocols 2 Choose Frame Relay Switch 3 Choose Interfaces The DLCMI Co...

Page 44: ... equivalent of one OC 3 line ATM PVCs configured for a slot Each virtual channel VCL statistics pertaining to an ATM configured slot VCL statistics are new for BayStream Version 7 3 To support VCL statistics collection in Site Manager the ATMizer VCL Bit Mask parameter has been added 4 1 list i wfFrSwDlcmiEntry BYS0094A TI list command instances show all instances of wfFrSwDlcmiEntry DLCMI MIB Ent...

Page 45: ... software gathers aggregates and reports for each virtual channel which congestion control is enabled A value of 1 within the bit mask indicates that the data collection software monitors and reports the associated congestion control counter a value of 0 within the bit mask indicates that the software ignores the associated congestion control counter The default value 0xFFFFFE00 monitors and repor...

Page 46: ...ata Collection window opens 3 Choose Global The Statistical Data Collection Parameters window opens 4 Choose Atmizer VCL Counter Bit Mask 5 Click on the Values button Site Manager displays a list of Atmizer VCL counters 6 Choose the counters you want to specify for data collection and reporting Site Manager displays the binary values that correspond to your slot selections in the Atmizer VCL Count...

Page 47: ...3 4 23 3 4 1 7 Yes 27 AtmizerVclRxOamCount 1 3 6 1 4 1 18 3 4 23 3 4 1 8 Yes 26 AtmizerVclRxFlowCtrlCount 1 3 6 1 4 1 18 3 4 23 3 4 1 9 Yes 25 AtmizerVclRxInvalidHeaders 1 3 6 1 4 1 18 3 4 23 3 4 1 10 Yes 24 AtmizerVclRxOversizedSDU s 1 3 6 1 4 1 18 3 4 23 3 4 1 11 Yes 23 AtmizerVclRxCrcErrors 1 3 6 1 4 1 18 3 4 23 3 4 1 12 Yes 22 AtmizerVclRxCrcIOErrors 1 3 6 1 4 1 18 3 4 23 3 4 1 13 Yes 21 Atmiz...

Page 48: ...lines are reported in bytes 17 AtmizerVclTxPacketsOkWra p 1 3 6 1 4 1 18 3 4 23 3 4 1 18 Yes 16 AtmizerVclTxPacketsOk 1 3 6 1 4 1 18 3 4 23 3 4 1 19 Yes 15 AtmizerVclTxCellsOkWrap 1 3 6 1 4 1 18 3 4 23 3 4 1 20 Yes 14 AtmizerVclTxCellsOk 1 3 6 1 4 1 18 3 4 23 3 4 1 21 Yes 13 AtmizerVclTxOamCount 1 3 6 1 4 1 18 3 4 23 3 4 1 22 Yes 12 AtmizerVclTxFlowCtrlCount 1 3 6 1 4 1 18 3 4 23 3 4 1 23 Yes 11 A...

Page 49: ...calls Site Manager Procedure You do this System responds 1 In the Configuration Manager window choose Options 2 Choose Line Byte Count The Add Line Byte Count window opens 3 Choose a configured circuit 4 Choose Add to make the circuit available for line byte count statistics collection 5 Choose Edit The Edit dialog box opens 6 Set the following parameters Enable Enable Stats Update Interval enter ...

Page 50: ...table 6 shows the field descriptions for the svcs option Table 6 svcs Field Descriptions Argument Meaning Circuit Number Contains the circuit number of the SVC Local DLCI Contains the number of the local DLCI Remote DLCI Contains the number of the remote DLCI Calling Number Contains the calling party number Called Number Contains the called party number Start Date Contains the date that the SVC wa...

Page 51: ...ne the link integrity of a circuit The status enquiry message contains five types of informational elements refer to Configuring Frame Relay Switching Services for a description of status enquiry messages One of these information elements the report type can be set to one of the following Full status Link integrity verification Single PVC asynchronous status The report type information element mus...

Page 52: ... a send sequence number matching the unique send sequence number then the loopback condition is confirmed Once the loopback condition is confirmed BayStream 1 Discards the second status message with the matching receive sequence number 2 Generates a Technician Interface log message of severity level warning for example cct 2 Loopback condition exists 3 Tears down the affected interface This means ...

Page 53: ...s have been increased by one BayStream software generates a severity level warning log message for example cct2 Loopback condition corrected Enabling Loopback Detection Using Site Manager To enable loopback detection perform the following steps Site Manager Procedure You do this System responds 1 In the Configuration Manager window choose Protocols 2 Choose Frame Relay Switch 3 Choose Interfaces S...

Page 54: ... Policing Disable You can enable or disable traffic policing on a user to network interface UNI or network to network NNI interface When traffic policing is enabled any traffic flow over the excess burst rate the sum of committed burst and excess burst is dropped and any traffic flow over the committed burst rate has the Discard Eligibility DE bit set meaning it is eligible for discard The default...

Page 55: ...s on an interface using either Site Manager or the Technician Interface Site Manager Procedure You do this System responds 1 In the Configuration Manager window choose Protocols 2 Choose Frame Relay Switch 3 Choose Interfaces Site Manager displays a list of frame relay switch interfaces 4 Select an interface 5 Choose Edit The Edit FRSW Interface window opens 6 Set the following parameter Burst Mea...

Page 56: ...1 Use the Technician Interface list command to display interfaces currently configured on the BayStream switch as shown in Figure 9 Site Manager Procedure You do this System responds 1 In the Configuration Manager window choose Protocols 2 Choose Frame Relay Switch 3 Choose Interfaces The DLCMI Configuration window opens 4 Click on Edit The Edit FRSW Interface window opens 5 At the Edit FRSW Inter...

Page 57: ...for a PVC on the interface Figure 11 shows an example of a Technician Interface set command which enables billing information collection for an SVC on the interface Figure 9 Displaying the Interfaces Figure 10 Enabling Billing Information Collection for PVCs on an Interface 4 1 list i wfFrSwDlcmiEntry BYS0094A TI list command instances show all instances of wfFrSwDlcmiEntry DLCMI MIB Entry 4 1 set...

Page 58: ...ynamic port number as the optional argument to a remote telnet command Figure 12 shows the format for a dynamic port number Figure 12 Configuring a Dynamic Port Number You can configure a local port prefix using Site Manager or the Technician Interface 4 1 set wfFrSwDlcmiEntry wfFrSwDlcmiSvcBillingEnable cct 1 BYS0100A TI set command DLCMI MIB entry attribute identifier attribute value 1 enable 2 ...

Page 59: ...this System responds 1 In the Configuration Manager window choose Protocols 2 Choose Global Protocols 3 Choose Telnet Server 4 Choose Global The Edit Telnet Server Global Parameters window opens 5 At the Edit Telnet Server Global Parameters window set the following parameter Local Port Prefix Valid values are 11 through 166 To disable the local port prefix feature set the parameter to 0 6 Click on...

Page 60: ...uide incorrectly states that Bay Networks supplies the Distinct TCP IP software with Site Manager Before installing Site Manager on a PC install any WINSOCK compatible TCP IP stack The booklet Installing BayStream Site Manager 7 2 accompanies the Site Manager CD Use this booklet in place of Chapter 1 Installing Site Manager in Getting Started with Site Manager Additions to Configuring Line Service...

Page 61: ...e of the following valid baud rates 1200 2400 4800 9600 14400 19200 28800 38400 57600 64000 76800 96000 115200 Setting the Synchronous IFTF Pattern The BayStream platform transmits one of two interframe time fill IFTF patterns when there is no data to transmit on a synchronous line HDLC Flags an 0x7E pattern 0 1 1 1 1 1 1 0 Idles an 0xFF pattern 1 1 1 1 1 1 1 1 HDLC Flags is the default IFTF patte...

Page 62: ...ocessing You must enable the Receive All Frames parameter when running frame relay switched virtual circuits SVCs on a HSSI circuit Changes to Configuring IP Services The OSPF software service is a soloist to conserve resources it runs on only one slot in the BayStream platform By default OSPF starts on the first available slot You can override this default by Restricting the slots eligible to run...

Page 63: ...the new configuration value the next time it boots Note Use the Values button to select the OSPF Slot options Parameter OSPF Slot Path Configuration Manager Protocols IP OSPF Global Default All slots Options Any slot on the router Function Identifies the slots the OSPF soloist is eligible to run on If the slot on which the OSPF soloist is running goes down the router will attempt to run OSPF on an...

Page 64: ...rts it starts on the highest priority slot available Instructions Leave blank to allow the BayStream platform to start OSPF on the first eligible slot to become available when the current OSPF process terminates Or enter a comma delimited list of the slots in order of priority Do not enter spaces Note If you use the OSPF Slot parameter to restrict the slots eligible to run OSPF the settings of thi...

Page 65: ...us OSYNC High Speed Serial Interface HSSI Test Traffic Generation requires that frames are HDLC type so that cyclic redundancy checks CRC can identify bad frames received during the loopback test Test Traffic Generation uses the BofL mechanism Parameter AS Boundary Router Path Configuration Manager Protocols IP OSPF Global Default Yes Options Yes No Function Indicates whether or not this router fu...

Page 66: ...raffic Generation is enabled the link management interface remains down 4 To disable Test Traffic Generation use the Technician Interface commands shown in Table 7 to set the MIB values to 2 For example use the following command to disable a HSSI line set wfHssiEntry wfHSSIBofl slot connector 2 commit Using Site Manager to Reallocate Memory Partitions for a Processor Module This section supplement...

Page 67: ...ing configuration If you move a FRE 2 to another slot the memory partitioning configuration moves with it You cannot partition NVRAM You can specify the amount of local and global memory that is the size of the local and global memory partitions used by a given processor module Increasing the size of the global memory partition automatically decreases the size of the local memory partition The Bay...

Page 68: ...onnection or select Options Connections The Switch Connection Options window appears Figure 14 Figure 14 Switch Connection Options Window 2 Enter the IP address of the BayStream platform that requires processor memory repartitioning and set the Timeout and Retries options Then click on OK 3 From the main Site Manager window select Administration Kernel Configuration The Kernel Configuration window...

Page 69: ...15 Kernel Configuration Window Note If the platform you are configuring has processor modules other than FRE 2 modules a window appears with the following message No valid modules were found The message means that the processor modules found in the currently connected BayStream platform are not user configurable ...

Page 70: ...Then drag the pointer to the chosen slot number and release the mouse button 5 Repartition the memory and restart the slot as described in Table 8 Memory Type for the Specified Slot Description Total on Specified Slot Memory dedicated to the local and global pools described below Dedicated to Local Pool Memory router management For example the local memory stores the statistics the event log the b...

Page 71: ...e You must also Save from the Configuration Manager File Save menu selection 3 Click on OK The slot restarts Repartition global memory to the local pool and restart the slot 1 Click on Down until the amount of memory you want appears or type a value next to the Dedicated to Global Pool parameter 2 Click on Update A window displays the prompt Save memory configuration for slot no Note You must also...

Page 72: ...t processor module if applicable Repeat Steps 1 through 6 to reallocate memory partitioning on a processor module in a different router 8 When you finish click on Done in the Kernel Configuration window The main Site Manager window reappears Correction to Running Diagnostics The first paragraph on page 3 23 of Troubleshooting and Testing incorrectly recommends that you issue the diags command afte...

Page 73: ... Action Enter a switch name that is six or fewer characters Entity Code Event Code FRSW 226 Decimal Identifier 16794082 Severity Warning Message No RNNI CFG found for Line Number line_no Meaning The RNNI interface configuration is incorrect Action Create wfFrSwRnniCfgEntry for the specified line number Entity Code Event Code FRSW 227 Decimal Identifier 16794083 Severity Warning Message NNI link on...

Page 74: ...85 Severity Warning Message NNI link on slot slot_no has transitioned to FULLUP state Meaning The RNNI interface on the specified slot has transitioned to the full_up state and is active Action Entity Code Event Code FRSW 234 Decimal Identifier 16794090 Severity Warning Message Circuit circuit_no loopback condition exists Meaning The specified circuit entered a loopback state Action Clear the loop...

Page 75: ...memory available Telnet Server Protocol TELNET Entity Code Event Code TELNET 31 Decimal Identifier 16787487 Severity Warning Message Dynamic Port Prefix is out of range Port Prefix set to value Valid value must be 0 or between value value Meaning The dynamic port prefix is invalid Action Change the port prefix to a value within the valid range STATS to DRAM Entity Code Event Code STATS 108 Decimal...

Page 76: ...age Error in compacting volume volume_id return GFS status DRAM VFS Meaning The statistical data collection software cannot compact the storage device Action Verify the integrity of the storage device Changes to MIBs The Volatile File System Table The Volatile File System table has been added to support the VFS extended file system Name wfFrSwExtFileSysTable Object ID 1 3 6 1 4 1 18 3 5 9 6 20 The...

Page 77: ...hen present contains a symbolic integer value of 1 indicating that this wfFrSwExtFileSysDelete instance has been created Name wfFrExtFileSysSlot Object ID 1 3 6 1 4 1 18 3 5 9 6 20 1 2 Type Integer Access Read Only Default None Description When present contains a unique value for a slot to which the VFS file extension is to be assigned to The slot value must be in the range between 1 and 14 Name w...

Page 78: ... has been enabled Some of the well known memory sizes and their corresponding values are shown in the following Name wfFrExtFileSysActualSize Object ID 1 3 6 1 4 1 18 3 5 9 6 20 1 4 Type Integer Access Read Only Default 0 Description Contains the actual size in bytes of the Volatile File System allocated A value of zero indicates that the extended file system is currently disabled Memory Size in b...

Page 79: ...for the failure is insufficient available memory 3 init Indicates that the extended file system is initializing and is not operational 4 notpresent Indicates that the current size of the extended file system is zero Resilient Network to Network Interface The following tables are new to the Frame Relay Switch MIB frsw mib RNNI DLCMI table RNNI Configuration CFG table The RNNI DLCMI Table Name wfFrS...

Page 80: ...iDlcmiMaxSupportedVCs wfFrSwRnniDlcmiVCsInUse wfFrSwRnniDlcmiSwitchHdrErrors wfFrSwRnniDlcmiSequenceCount wfFrSwRnniDlcmiLastReceived wfFrSwRnniDlcmiActiveSeqCount wfFrSwRnniDlcmiActiveReceived wfFrSwRnniDlcmiPolls wfFrSwRnniDlcmiAlarmTimer wfFrSwRnniDlcmiErrType wfFrSwRnniDlcmiErrData wfFrSwRnniDlcmiErrTime wfFrSwRnniDlcmiBcMeasurementInterval wfFrSwRnniDlcmiMcastNoBufferErrors wfFrSwRnniDlcmiFra...

Page 81: ...olls wfFrSwRnniDlcmiDtePollingInterval wfFrSwRnniDlcmiDteFullEnquiryInterval wfFrSwRnniDlcmiDteErrorThreshold wfFrSwRnniDlcmiCrossNetEnable wfFrSwRnniDlcmiCrossNetPolling Interval wfFrSwRnniDlcmiCrossNetErrorThreshold wfFrSwRnniDlcmiCrossNetAsyncUpdateEnable wfFrSwRnniDlcmiBcMeasurementEnable wfFrSwRnniDlcmiAsyncUpdateEnable wfFrSwRnniDlcmiCrossNetListenEnable wfFrSwRnniDlcmiSvcDisable wfFrSwRnniD...

Page 82: ...ss Read Only Default 1 created Description When present contains a symbolic integer value of 1 indicating that this wfFrSwRnniEntry instance has been created or 2 indicating that this entry has been deleted Name wfFrSwRnniDlcmiState Object ID 1 3 6 1 4 1 18 3 5 9 6 22 1 2 Type Integer Access Read Only Default 3 initializing Description Contains a symbolic integer value that specifies the state of ...

Page 83: ...nable is set by Site Manager this object is not used by the frame relay switch software Refer to wfFrSwRnniDlcmiBidirect Name wfFrSwRnniDlcmiCircuit Object ID 1 3 6 1 4 1 18 3 5 9 6 22 14 Type Integer Access Read Only Description Specifies the circuit number of this entry Name wfFrSwRnniDlcmiManagementType Object ID 1 3 6 1 4 1 18 3 5 9 6 22 1 5 Type Integer Access Read Only Default 3 ANSI T1 671 ...

Page 84: ...Only Description Contains the level 3 IP address of this frame relay interface Name wfFrSwRnniDlcmiAddressLen Object ID 1 3 6 1 4 1 18 3 5 9 6 22 1 7 Type Integer Access Read Only Default 2 twobyte Description Contains the address length including the control portion 2 twobyte a two byte address 3 threebyte a three byte address 4 fourbyte a four byte address Name wfFrSwRnniDlcmiControlByteDisable ...

Page 85: ...nteger Access Read Only Default 6 inquiries Description Contains the number of status enquiries which are received between full status enquiries This applies to bidirectional procedures only Name wfFrSwRnniDlcmiErrorThreshold Object ID 1 3 6 1 4 1 18 3 5 9 6 22 1 11 Type Integer Access Read Only Default 3 errors Description Contains the number of errors monitored before declaring the interface dow...

Page 86: ...uits allowed on the interface Name wfFrSwRnniDlcmiVCsInUse Object ID 1 3 6 1 4 1 18 3 5 9 6 22 1 15 Type Integer Access Read Only Description Contains the number of virtual circuits currently configured on the interface Name wfFrSwRnniDlcmiSwitchHdrErrors Object ID 1 3 6 1 4 1 18 3 5 9 6 22 1 16 Type Integer Access Read Only Description Contains the number of frames dropped because they were recei...

Page 87: ...the value of the sending status inquiry sequence counter for bidirectional procedures only Name wfFrSwRnniDlcmiActiveReceived Object ID 1 3 6 1 4 1 18 3 5 9 6 22 1 20 Type Integer Access Read Only Default 1 sequence number Description Contains the most recent sequence number received from the inquiring station Name wfFrSwRnniDlcmiPolls Object ID 1 3 6 1 4 1 18 3 5 9 6 22 1 21 Type Integer Access R...

Page 88: ...ket addressed to an illegal DLCI 6 the reception of a data packet addressed to a valid but unconfigured DLCI 7 a management protocol violation 8 the reception of management packet that contained a sequence error 9 the reception of a management packet that contained a faulty Report_Type IE 10 a Q922 control byte error 11 the reception of a packet that contained a header error refer to wfFrSwDlcmiSw...

Page 89: ...at a multicast message failed because there were insufficient buffers available to create multiple copies of a multicast frame Name wfFrSwRnniDlcmiFrameTooShortErrors Object ID 1 3 6 1 4 1 18 3 5 9 6 22 1 28 Type Counter Access Read Only Description Contains the number of frames dropped that were too short to be accepted Name wfFrSwRnniDlcmiFrameTooLongErrors Object ID 1 3 6 1 4 1 18 3 5 9 6 22 1 ...

Page 90: ...rames dropped because of a DLCMI protocol violation Name wfFrSwRnniDlcmiUnknownIEErrors Object ID 1 3 6 1 4 1 18 3 5 9 6 22 1 33 Type Counter Access Read Only Description Contains the number of frames dropped that contained an unknown information element Name wfFrSwRnniDlcmiSequenceErrors Object ID 1 3 6 1 4 1 18 3 5 9 6 22 1 34 Type Counter Access Read Only Description Contains the number of fram...

Page 91: ...6 22 1 37 Type Counter Access Read Only Description Contains the number of frames dropped that contained a frame format error Name wfFrSwRnniDlcmiOtherErrors Object ID 1 3 6 1 4 1 18 3 5 9 6 22 1 38 Type Counter Access Read Only Description Contains the number of frames dropped because they contained unknown errors or errors not counted by any error counter Name wfFrSwRnniDlcmiStatus Object ID 1 3...

Page 92: ...recently deleted PVCs that the CPE had not been informed about by means of a full status message Name wfFrSwRnniDlcmiFullStatusSeq Object ID 1 3 6 1 4 1 18 3 5 9 6 22 1 42 Type Counter Access Read Only Description Contains the expected sequence number for the next status enquiry message that will verify that the CPE received the last full status message and is aware of newly added and deleted PVCs...

Page 93: ... Integer Access Read Only Default 1 sequence number Description Contains the sequence number for the BayStream switch for the sending enquiry message for bidirectional procedures Name wfFrSwRnniDlcmiDteReceived Object ID 1 3 6 1 4 1 18 3 5 9 6 22 1 46 Type Integer Access Read Only Default 1 sequence number Description Contains the sequence number just received from the enquiring station for bidire...

Page 94: ...ult 10 seconds Description Contains the number of seconds between successive status enquiry messages Name wfFrSwRnniDlcmiDteFullEnquiryInterval Object ID 1 3 6 1 4 1 18 3 5 9 6 22 1 50 Type Integer Access Read Only Default 6 sequence number Description Specifies the number of status inquiry messages to be received before a full status enquiry message for bidirectional procedures Name wfFrSwRnniDlc...

Page 95: ...ion Contains the number of seconds between successive status enquiry messages Name wfFrSwRnniDlcmiCrossNetErrorThreshold Object ID 1 3 6 1 4 1 18 3 5 9 6 22 1 54 Type Integer Access Read Only Default 3 missed heartbeat polls Description Contains the number of missed heartbeat polls before BayStream software declares the cross net PVC inactive Name wfFrSwRnniDlcmiCrossNetAsyncUpdateEnable Object ID...

Page 96: ...led Description Contains a symbolic integer value of 1 indicating that the link management entity should send an asynchronous single PVC update message when the state of a PVC is changed by a network operator or by cross net polling procedures Name wfFrSwRnniDlcmiCrossNetListenEnable Object ID 1 3 6 1 4 1 18 3 5 9 6 22 1 58 Type Integer Access Read Only Default 2 disabled Description Contains a sy...

Page 97: ...er Access Read Only Default 1 none Description Identifies the escape mode none ingress or egress to be used for PVCs when wfFrSwVcEscapeMode is set to enabled Name wfFrSwRnniDlcmiEscapeCircuit Object ID 1 3 6 1 4 1 18 3 5 9 6 22 1 62 Type Integer Access Read Only Default No default Description Identifies the FR DTE circuit number corresponding to an escape PVC This attribute only applies to PVCs w...

Page 98: ...FrSwRnniDlcmiSvcBillingEnable Object ID 1 3 6 1 4 1 18 3 5 9 6 22 1 65 Type Integer Access Read Only Default 1 enabled Description Symbolic integer which indicates whether SVC billing on this access channel is set to enabled 1 or disabled 2 Name wfFrSwRnniDlcmiSpvcAgent Object ID 1 3 6 1 4 1 18 3 5 9 6 22 1 66 Type Integer Access Read Only Default None Description Specifies which one of the follow...

Page 99: ... requests with the wrong selection type are rejected by BayStream software Name wfFrSwRnniDlcmiBillingEnable Object ID 1 3 6 1 4 1 18 3 5 9 6 22 1 68 Type Integer Access Read Only Default 2 enabled Description Contains a symbolic integer which indicates whether the PVC billing on this access channel is set to disabled 1 or enabled 2 Name wfFrSwRnniDlcmiSvcStatsEnable Object ID 1 3 6 1 4 1 18 3 5 9...

Page 100: ...ect ID 1 3 6 1 4 1 18 3 5 9 6 22 1 71 Type Integer Access Read Only Default 2 disabled Description A symbolic integer which indicates whether the Annex A software loopback detection feature is enabled 1 or disabled 2 Name wfFrSwRnniDlcmiLineNumber Object ID 1 3 6 1 4 1 18 3 5 9 6 22 1 72 Type Integer Access Read Only Default No default Description Contains the instance identifier for this entry Na...

Page 101: ...he init state 5 tofullup the link is fully operational 6 dlcmifault the link is experiencing a DLCMI MIB misconfiguration 7 rnnicfgfault the link is experiencing Resilient NNI configuration mismanagement 8 notpres the RNNI entity is not present on this link The RNNI Configuration CFG Table Name wfFrSwRnniCfgTable Object ID 1 3 6 1 4 1 18 3 5 9 6 23 The MIB objects in the Resilient Network to Netwo...

Page 102: ...the alternate link recieves LIV from the master node 2 livdown the alternate link does not receive LIV messages from the master node or has just transitioned from the dlcmiup state 3 dlcmiup the link is fully operational and is exchanging bidirectional Annex A messages with the master node 4 livnit the link is in the init state 5 tofullup the link is fully operational 6 dlcmifault the link is expe...

Page 103: ...None Description Associates this configuration Resilient NNI entry with the DLCMI entry Name wfFrSwRnniCfgDebugLevel Object ID 1 3 6 1 4 1 18 3 5 9 6 23 1 6 Type Integer Access Read Only Default None Description Contains the debug level 1 none No debug information is displayed in the log file 2 high Related Resilient NNI function names are displayed in the log file 3 detailed Log message of high l...

Page 104: ...n the RNNI interface Entries are indexed by the wfFrSwRnniVcCircuit and wfFrSwRnniVcDlci objects Name wfFrSwRnniVcEntry Object ID 1 3 6 1 4 1 18 3 5 9 6 24 1 Index wfFrSwRnniVcLineNumber wfFrSwRnniVcDlci Each entry contains the following objects wfFrSwRnniVcDelete wfFrSwRnniVcCircuit wfFrSwRnniVcDlci wfFrSwRnniVcState wfFrSwRnniVcStateSet wfFrSwRnniVcMulticast wfFrSwRnniVcInBe wfFrSwRnniVcOutBe wf...

Page 105: ...niVcSetFecnFrames wfFrSwRnniVcSetFecnOctets wfFrSwRnniVcSetBecnFrames wfFrSwRnniVcSetBecnOctets wfFrSwRnniVcSetDeFrames wfFrSwRnniVcSetDeOctets wfFrSwRnniVcDropNonDeFrames wfFrSwRnniVcDropNonDeOctets wfFrSwRnniVcDropDeFrames wfFrSwRnniVcDropDeOctets wfFrSwRnniVcInactiveVcDropFrames wfFrSwRnniVcInactiveVcDropOctets wfFrSwRnniVcRecvNonDeFrames wfFrSwRnniVcRecvNonDeOctets wfFrSwRnniVcRecvDeFrames wfF...

Page 106: ...pCalledDlci wfFrSwRnniVcBackupCrossNetStatus wfFrSwRnniVcBackupCrossNetErrors wfFrSwRnniVcAtmIwfMode wfFrSwRnniVcAtmIwfVPI wfFrSwRnniVcAtmIwfVCI wfFrSwRnniVcAtmIwfLossPriorityPolicy wfFrSwRnniVcAtmIwfDePolicy wfFrSwRnniVcAtmIwfEfciPolicy wfFrSwRnniVcEscapeEnable wfFrSwRnniVcSpvcCallState wfFrSwRnniVcCallReqCalledAddr wfFrSwRnniVcCallReqDlciSelectionType wfFrSwRnniVcCallReqCalled Dlci wfFrSwRnniVcC...

Page 107: ...rSwRnniVcCircuit Object ID 1 3 6 1 4 1 18 3 5 9 6 24 2 Type Integer Access Read Only Default Null Description Derived from and identical to wfFrSwDlcmiCircuit The wfFsSwRnniVcCircuit attribute associates this wfFrSwRnniVcEntry with a specific DLCMI instance and provides an index into wfFrSwRnniVcEntry Name wfFrSwRnniVcDlci Object ID 1 3 6 1 4 1 18 3 5 9 6 24 3 Type Integer Access Read Only Default...

Page 108: ...ve state until deactivated by the user with wfFrSwRnniVcStateSet at which point it transitions to the deactivated by user state or until DLCMI excessive protocol violations are monitored at which point it transitions to the inactive state 3 identifies the inactive state The inactive state specifies that excessive DLCMI protocol violations have taken the underlying frame relay access line and all P...

Page 109: ...ream frame relay switch software transitions the PVC directly to the active state Name wfFrSwRnniVcMulticast Object ID 1 3 6 1 4 1 18 3 5 9 6 24 6 Type Integer Access Read Write Default 2 Unicast Description Contains a symbolic integer value that identifies the PVC type 2 designates a Unicast PVC 1 designates a Multicast PVC Name wfFrSwRnniVcInBe Object ID 1 3 6 1 4 1 18 3 5 9 6 24 7 Type Integer ...

Page 110: ...ains the incoming throughput for the PVC Incoming throughput is the average number of CPE generated information field bits over a measured interval of time Refer to wfFrSwRnniVcInBc on wfFrSwBcMeasurementInterval and wfFrSwDlcmiBcMeasurementEnable on Name wfFrSwRnniVcOutThroughput Object ID 1 3 6 1 4 1 18 3 5 9 6 24 10 Type Integer Access Read Write Default Null Description This object is not used...

Page 111: ...BcMeasurementEnable Bc is defined by the formula Bc Throughput Measured Interval where Throughput wfFrSwRnniVcInThroughput Measured Interval wfFrSwBcMeasurementInterval Name wfFrSwRnniVcInBcOctets Object ID 1 3 6 1 4 1 18 3 5 9 6 24 13 Type Integer Access Read Only Default Null Description Specifies the incoming committed burst size Bc for the PVC in bytes Refer to wfFrSwRnniVcInBc on Name wfFrSwR...

Page 112: ... NNI or 3 to both of these customers To determine the advertised state DLCMI consults wfFrSwRnniVcState which contains the PVC state as determined by DLCMI wfFrSwRnniVcReceivedStatus which contains the PVC state as reported by the remote side of an NNI and wfFrSwRnniVcCrossNetStatus which contains the PVC state as reported by the switch at the remote end of the PVC segment When all three values co...

Page 113: ... Type Integer Access Read Only Default 2 active Description Contains a symbolic integer value of 1 Inactive or 2 Active that specifies the PVC state as reported by the remote end of the PVC segment DLCMI updates wfFrSwRnniVcCrossNetStatus in response to status reports received from the remote end of the PVC segment The wfFrSwRnniVcCrossNetStatus attribute is nonfunctional if either or both wfFrSwD...

Page 114: ...eived when the polling cycle expires Name wfFrSwRnniVcCalledIpAddr Object ID 1 3 6 1 4 1 18 3 5 9 6 24 20 Type IP Address Access Read Write Default Null Description Contains the IP address of the remote end of the PVC This IP address may be serviced by this BayStream platform local to local switching or by another BayStream platform accessed over the switched network remote to local switching Name...

Page 115: ...s PVC be tagged priority 1 2 Medium all user generated traffic entering the network via this PVC be tagged priority 2 3 Low all user generated traffic entering the network via this PVC be tagged priority 3 999 all user generated traffic entering the network via this PVC be tagged with the port specific priority value assigned by the wfCctOptsCngcPortTrfPriority object Traffic priority and discarda...

Page 116: ...ftware transmitted across the access line to the CPE or associated switch on an NNI This counter is maintained by the BayStream congestion control software and periodically read by the BayStream billing software as it prepares billing files refer to wfFrSwUsageUpdateInterval Note The following objects quantify PVC specific traffic flow across frame relay access lines that is UNIs user to network i...

Page 117: ...l Description Contains the number of discard eligible frames DE bit was set to 1 addressed to wfFrSwRnniVcDlci that the BayStream frame relay switch software transmitted across the access line to the CPE or associated switch on an NNI This counter is maintained by the BayStream congestion control software and periodically read by the BayStream billing software as it prepares billing files refer to...

Page 118: ...pe Counter Access Read Only Default Null Description Indicates the number of octets in frames sent to the interface in which this switch set the FECN bit Name wfFrSwRnniVcSetBecnFrames Object ID 1 3 6 1 4 1 18 3 5 9 6 24 31 Type Counter Access Read Only Default Null Description Indicates the number of frames sent to the interface in which this switch set the BECN bit Name wfFrSwRnniVcSetBecnOctets...

Page 119: ...Description Indicates the number of octets in frames sent to the interface in which this switch set the DE bit Name wfFrSwRnniVcDropNonDeFrames Object ID 1 3 6 1 4 1 18 3 5 9 6 24 35 Type Counter Access Read Only Default Null Description Indicates the number of frames received over the interface that were discarded excluding any frames in which the DE bit was set Name wfFrSwRnniVcDropNonDeOctets O...

Page 120: ...rded Name wfFrSwRnniVcInactiveVcDropFrames Object ID 1 3 6 1 4 1 18 3 5 9 6 24 39 Type Counter Access Read Only Default Null Description This counter which is maintained by the BayStream congestion control software contains the number of frames addressed to wfFrSwRnniVcDlci that the BayStream frame relay switch software dropped because the PVC was inactive refer to wfFrSwRnniVcState Name wfFrSwRnn...

Page 121: ...9 6 24 42 Type Counter Access Read Only Default Null Description Indicates the number of octets received on this virtual circuit over the interface Name wfFrSwRnniVcRecvDeFrames Object ID 1 3 6 1 4 1 18 3 5 9 6 24 43 Type Counter Access Read Only Default Null Description Indicates the number of frames received over this interface in which the DE bit was set Name wfFrSwRnniVcRecvDeOctets Object ID ...

Page 122: ...Type Counter Access Read Only Default Null Description Indicates the number of octets in frames received over the interface in which the FECN bit was set Name wfFrSwRnniVcRecvBecnFrames Object ID 1 3 6 1 4 1 18 3 5 9 6 24 47 Type Counter Access Read Only Default Null Description Indicates the number of frames received over the interface in which the BECN bit was set Name wfFrSwRnniVcRecvBecnOctets...

Page 123: ... the expiration of each cross network polling cycle in which a poll was not received from the remote end of the PVC segment and compares this value with wfFrSwDlcmiCrossNetErrorThreshold If these values are equal DLCMI takes the PVC down and advertises the PVC as Inactive At the expiration of each polling cycle in which a cross network poll was received DLCMI resets wfFrSwRnniVcXNetErrors to 0 zer...

Page 124: ...ntInterval to calculate wfFrSwRnniVcInBe Name wfFrSwRnniVcRedirectAction Object ID 1 3 6 1 4 1 18 3 5 9 6 24 55 Type Integer Access Read Only Default 2 redirecttoprimary Description Indicates whether the switch will redirect the PVC source manually or based on cross network updates 2 the switch will manually redirect the PVC source to the primary circuit 3 the switch will manually redirect the PVC...

Page 125: ... Inactive backup is not configured and or cross network status is inactive will allow traffic only through primary 2 Primary Active both primary and backup received active cross network status currently primary is active and traffic is only through primary 3 Switch to Backup primary cross network status is inactive but cannot switch to backup due to manual or semimanual operation of the redirect w...

Page 126: ...t ID 1 3 6 1 4 1 18 3 5 9 6 24 59 Type Integer Access Read Only Default Null Description Contains the backup called DLCI of the remote end of the PVC Values may be 16 two byte minimum 1007 two byte maximum 1024 three byte minimum 64511 three byte maximum 131072 four byte minimum 8257535 four byte maximum Name wfFrSwRnniVcBackupCrossNetStatus Object ID 1 3 6 1 4 1 18 3 5 9 6 24 60 Type Integer Acce...

Page 127: ... 1 3 6 1 4 1 18 3 5 9 6 24 62 Type Integer Access Read Only Default 2 Description Specifies the mode of frame relay ATM interworking over this frame relay PVC or that frame relay ATM interworking is not enabled for this PVC 2 Transparent mode 3 Translation mode 4 Network Enable mode Name wfFrSwRnniVcAtmIwfVPI Object ID 1 3 6 1 4 1 18 3 5 9 6 24 63 Type Integer Access Read Only Default 0 Descriptio...

Page 128: ...teger Access Read Only Default 1 Description Indicates the policy for translating ATM CLP to FR DE on this PVC or simply sets FR DE to a constant value for all frames This parameter is relevant only when the frame relay ATM interworking is enabled for this PVC 1 Map ATM CLP to frame relay DE 2 Set DE to 1 3 Set DE to 0 Name wfFrSwRnniVcAtmIwfDePolicy Object ID 1 3 6 1 4 1 18 3 5 9 6 24 66 Type Int...

Page 129: ... ID 1 3 6 1 4 1 18 3 5 9 6 24 68 Type Integer Access Read Only Default 2 Disabled Description If you use the default setting 2 Disabled the PVC behaves as a standard frame relay switch PVC If you set this object to 1 Enabled the PVC becomes a gateway PVC to IP The setting of the wfFrSwDlcmiEscapeMode object determines the type of gateway PVC If you want the BayStream platform on the first segment ...

Page 130: ...5 9 6 24 70 Type Integer Access Read Only Description Indicates the called E 164 X 121 address for an SPVC call request agent The address type is determined by the wfFrSwDlcmiL2AddrType attribute in the wfFrSwDlcimiEntry Name wfFrSwRnniVcCallReqDlciSelectionType Object ID 1 3 6 1 4 1 18 3 5 9 6 24 71 Type Integer Access Read Only Default 1 any Description Indicates to the calling end of an SPVC ca...

Page 131: ...4 1 18 3 5 9 6 24 73 Type Integer Access Read Only Default 3 minutes Description Indicates the number of minutes the call request agent should wait for an SPVC connect message before declaring a call setup request rejected Name wfFrSwRnniVcCallReqMaxRetries Object ID 1 3 6 1 4 1 18 3 5 9 6 24 74 Type Integer Default 21474883647 Description Indicates the number of times the call request agent shoul...

Page 132: ...Default None Description Specifies the type of addressing format X121 or E164 Name wfFrSwRnniVcLineNumber Object ID 1 3 6 1 4 1 18 3 5 9 6 24 78 Type Integer Access Read Only Default No default Description Specifies one of the instance identifiers for this entry Data Link Connection Management Interface The following attribute is new to the wfFrSwDclmiEntry table Name wfFrSwDlcmiBillingEnable Obje...

Page 133: ...fFrSwDlcmiLoopback Status Object ID 1 3 6 1 4 1 18 3 5 9 6 1 1 70 Type Integer Access Read Only Default Disabled Description Indicates the current state of the network equipment regarding Loopback condition Possible states are normal 1 suspected 2 loopback 3 Name wfFrSwDlcmiLoopbackEnable Object ID 1 3 6 1 4 1 18 3 5 9 6 1 1 71 Type Integer Access Read Write Default Disabled Description This attri...

Page 134: ...shold the driver never enters the carrier lost state Name wfHssiModule Object ID 1 3 6 1 4 1 18 3 4 7 1 65 Type Integer Access Read Only Default No default Description Module number for the ASN platform filled in by the driver For non ASN platforms this attribute is not used Name wfHssiActualConnector Object ID 1 3 6 1 4 1 18 3 4 7 1 66 Type Integer Access Read Only Default No default Description ...

Page 135: ...tribute when enabled 1 signifies that this HSSI device driver is running frame relay switch WAN protocol and is configured for Resilient NNI Statistical Data Collection Name wfStatsDcAtmzVclFields Object ID 1 3 6 1 4 1 18 3 3 2 17 1 22 Type Gauge Access Read Write Default 0xFFFFFE00 Description Contains a 32 position bit mask specifying the ATM VCL counters that the BayStream data collection softw...

Page 136: ...3 4 1 12 Yes 22 AtmizerVclRxCrcIOErrors 1 3 6 1 4 1 18 3 4 23 3 4 1 13 Yes 21 AtmizerVclRxLackBufCredits 1 3 6 1 4 1 18 3 4 23 3 4 1 14 Yes 20 AtmizerVclRxLackPageCredit 1 3 6 1 4 1 18 3 4 23 3 4 1 15 Yes 19 AtmizerVclRxBufResc 1 3 6 1 4 1 18 3 4 23 3 4 1 16 Yes 18 AtmizerVclRxPageResc 1 3 6 1 4 1 18 3 4 23 3 4 1 17 Yes 17 AtmizerVclTxPacketsOkWrap 1 3 6 1 4 1 18 3 4 23 3 4 1 18 Yes 16 AtmizerVclT...

Page 137: ...e Virtual Circuit Table Name wfFrSwVcCalledNumber Object ID 1 3 6 1 4 1 18 3 5 9 6 7 1 75 Type Octet String Access Read Only Default No default Description Specifies the called party number Name wfFrSwVcCallingNumber Object ID 1 3 6 1 4 1 18 3 5 9 6 7 1 76 Type Octet String Access Read Only Default No default Description Specifies the calling party number Name wfFrSwVcAddressType Object ID 1 3 6 1...

Page 138: ...guration Manager Protocols Frame Relay Switch PVCs Permanent VCs Edit Default MAP FR FECN TO ATM EFCI Options MAP FR FECN TO ATM EFCI SET FECN TO 1 SET FECN TO 0 Function Indicates the policy for translating frame relay forward explicit congestion notification FECN to ATM explicit forward congestion indication EFCI on this frame relay PVC or setting FR FECN to a constant value for all frames This ...

Page 139: ...olicy for translating frame relay forward explicit congestion notification FECN to ATM explicit forward congestion indication EFCI on this frame relay PVC or setting FR FECN to a constant value for all frames This parameter is relevant only when frame relay to ATM interworking is enabled for this PVC Instructions Accept the default MIB Object ID 1 3 6 1 4 1 18 3 5 9 6 7 1 67 Parameter VCI Number P...

Page 140: ...eader The header can contain a maximum of 16 VCI bits Instructions Enter a value from 32 through 8191 MIB Object ID 1 3 6 1 4 1 18 3 4 23 1 5 1 4 Parameter VCI Number Path Configuration Manager Protocols ATM DXI Interfaces Default None Options 32 to 8191 Function Identifies the virtual channel of the PVC Instructions How you set this parameter depends on how you set the DXI Mode parameter in the A...

Reviews: