I/O Memory Allocation
Section 9-3
225
Address CS/CJ-series
PLC
CX-Simulator
Words Bits
Name
Function Settings
Function
Settings
A403 A40309
Memory
Card
Start-up
Transfer
Error Flag
ON when automatic transfer at
startup has been selected and an
error occurs during automatic
transfer. An error will occur if
there is a transfer error, the
specified file does not exist, or the
Memory Card is not installed.
(This flag will be turned OFF
when the error is cleared by
turning the power off. The error
cannot be cleared without turning
the power off.)
1: Error
0: No error
Same as
CS/CJ-series
PLC.
A40400
to
A40407
I/O Bus
Error Slot
Number
Contains the 8-bit binary slot
number (00 to 09) where an I/O
Bus Error occurred.
1: Error
0: No error
Not used.
A404
A40408
to
A40415
I/O Bus
Error Rack
Number
Contains the 8-bit binary rack
number (00 to 07) where an I/O
Bus Error occurred.
1: Error
0: No error
Not used.
A405 A40500
and
A40501
SYSMAC
BUS Mas-
ter Flags
When a transmission error occurs
in the SYSMAC BUS system, the
flag for the affected Master Unit
will be turned ON.
A40500: Flag for Master Unit #0
A40501: Flag for Master Unit #1
1: Error
0: No error
Not used.
A406 All
PLC
Setup
Error Loca-
tion
When there is a setting error in
the PLC Setup, the location of
that error is written to A406 in
4-digit hexadecimal. The location
is given as the address displayed
on a Programming Console.
The CPU Unit will continue oper-
ating and the ERR/ALM indicator
on the front of the CPU Unit will
flash.
(A406 will be cleared when the
cause of the error is eliminated.)
000A to
009F
hexadeci-
mal
Same as
CS/CJ-series
PLC.
Summary of Contents for CX-Simulator 1.9
Page 1: ...Cat No W366 E1 10 CX Simulator Ver 1 9 SYSMAC WS02 SIMC1 E OPERATION MANUAL...
Page 2: ......
Page 3: ...SYSMAC WS02 SIMC1 E CX Simulator Ver 1 9 Operation Manual Revised December 2009...
Page 24: ...xxv...
Page 30: ...xxxi...
Page 35: ...xxxvi...
Page 39: ......
Page 63: ...Comparison of the CX Simulator and SYSMAC CS CJ series PLCs Section 1 6 24...
Page 75: ...Installing and Uninstalling the Software Section 2 1 36...
Page 157: ...Task Debugging Section 4 4 118...
Page 195: ...Connection with Application Programs Section 7 2 156...
Page 225: ...Checking the Result Section 8 5 186...
Page 277: ...Other Functions Section 9 4 238...
Page 289: ...Other Tips for Troubleshooting Section 10 3 250...
Page 304: ......
Page 305: ......