FT DRAFT DRAFT DRAFT DRA
UM10316_0
© NXP B.V. 2008. All rights reserved.
User manual
Rev. 00.06 — 17 December 2008
411 of 571
NXP Semiconductors
UM10316
Chapter 23: LPC2xx I2C-interface
9.5 Miscellaneous states
There are two I2STAT codes that do not correspond to a defined I
2
C hardware state (see
). These are discussed below.
23.9.5.1 I2STAT = 0xF8
This status code indicates that no relevant information is available because the serial
interrupt flag, SI, is not yet set. This occurs between other states and when the I
2
C block
is not involved in a serial transfer.
23.9.5.2 I2STAT = 0x00
This status code indicates that a bus error has occurred during an I
2
C serial transfer. A
bus error is caused when a START or STOP condition occurs at an illegal position in the
format frame. Examples of such illegal positions are during the serial transfer of an
address byte, a data byte, or an acknowledge bit. A bus error may also be caused when
external interference disturbs the internal I
2
C block signals. When a bus error occurs, SI is
set. To recover from a bus error, the STO flag must be set and SI must be cleared. This
causes the I
2
C block to enter the “not addressed” slave mode (a defined state) and to
clear the STO flag (no other bits in I2CON are affected). The SDA and SCL lines are