3. Parameters
3.2 Parameter list (by parameter number)
1
2
3
4
5
6
7
8
9
10
Pr.200 to Pr.299
Function
Pr.
Pr.
group
Name
Setting range
Minimum
setting
increments
Initial
value
Refer
to page
Customer
setting
Gr.1
Gr.2
Multi-
spee
d set
ting
232 to
239
D308 to
D315
Multi-speed setting (speed 8
to speed 15)
0 to 590 Hz, 9999
0.01 Hz
9999
—
240
E601
Soft-PWM operation
selection
0, 1
1
1
—
241
M043
Analog input display unit
switchover
0, 1
1
0
—
244
H100
Cooling fan operation
selection
0, 1
1
1
Slip co
mp
ensat
ion
245
G203
Rated slip
0% to 50%, 9999
0.01%
9999
246
G204
Slip compensation time
constant
0.01 to 10 s
0.01 s
0.5 s
247
G205
Constant output range slip
compensation selection
0, 9999
1
9999
—
249
H101
Earth (ground) fault detection
at start
0, 1
1
0
1
—
250
G106
Stop selection
0 to 100 s, 1000 to
1100 s, 8888, 9999
0.1 s
9999
—
251
H200
Output phase loss protection
selection
0, 1
1
1
Lif
e che
ck
255
E700
Life alarm status display
(0 to 879)
1
0
256
E701
Inrush current limit circuit life
display
(0% to 100%)
1%
100%
257
E702
Control circuit capacitor life
display
(0% to 100%)
1%
100%
258
E703
Main circuit capacitor life
display
(0% to 100%)
1%
100%
259
E704
Main circuit capacitor life
measuring
0, 1
1
0
—
260
E602
PWM frequency automatic
switchover
0, 10
1
10
Power failure stop
261
A730
Power failure stop selection
0 to 2
1
0
—
267
T001
Terminal 4 input selection
0 to 2
1
0
—
268
M022
Monitor decimal digits
selection
0, 1, 9999
1
9999
—
269
E023
Parameter for manufacturer setting. Do not set.
Sto
p
-o
n-
con
tact
con
trol
270
A200
Stop-on-contact control
selection
0, 1, 11
1
0
275
A205
Stop-on contact excitation
current low-speed scaling
factor
0% to 300%, 9999
0.1%
9999
276
A206
PWM carrier frequency at
stop-on contact
0 to 9, 9999
1
9999
277
H630
Stall prevention operation
current switchover
0, 1
1
0
Summary of Contents for FR-E800
Page 17: ...16 1 Introduction 1 3 Related manuals MEMO ...
Page 51: ...50 2 Basic Operation 2 8 I O terminal function assignment MEMO ...
Page 89: ...88 3 Parameters 3 4 Parameter list by function group number MEMO ...
Page 135: ...134 5 Speed Control 5 9 Troubleshooting in the speed control MEMO ...
Page 153: ...152 6 Torque Control 6 7 Troubleshooting in torque control MEMO ...
Page 195: ...194 8 E Environment Setting Parameters 8 18 Current average value monitor signal MEMO ...
Page 237: ...236 10 D Operation Command and Frequency Command 10 6 Operation by multi speed setting MEMO ...
Page 339: ...338 13 T Multi Function Input Terminal Parameters 13 9 Start signal operation selection MEMO ...
Page 455: ...454 16 G Control Parameters 16 13 Speed smoothing control MEMO ...