12. (M) Item and Output Signal for Monitoring
12.6 Output terminal function selection
• The Inverter running and start command ON (RUN3) signal is ON while the inverter is running or while the start command
signal is ON (When the start command signal is ON, the RUN3 signal is ON even while the inverter's protective function
is activated or while the MRS signal is ON.) The RUN3 signal is ON even during the DC injection brake operation, and the
signal is OFF when the inverter stops.
• The ON/OFF state of each signal according to the inverter operating status is shown in the matrix below.
*1
The signal is OFF during power failure or undervoltage.
*2
This means the state during a fault occurrence or while the MRS signal is ON, etc.
*3
The signal is OFF while power is not supplied to the main circuit.
Operation under Real sensorless vector control, Vector control, and PM sensorless vector
control
• When the inverter is ready for operation, the Inverter operation ready (RY) signal turns ON (and stays ON during
operation).
• When the inverter output frequency reaches the setting of
Pr.13 Starting frequency
or higher, the Inverter running (RUN)
turns ON. The signal is OFF during an inverter stop, during the DC injection brake operation, during tuning at start-up, or
during pre-excitation.
• The Inverter running 2 (RUN2) signal is ON while the inverter is running or while the start command signal is ON. (When
the inverter's protective function is activated or the MRS signal is ON, the RUN2 signal turns OFF.)
• The Inverter running and start command ON (RUN3) signal is ON while the inverter is running or while the start command
signal is ON.
• The RUN2 and RUN3 signals are also ON when the start command signal is ON or during pre-excitation with the speed
command value 0. (However, the RUN2 signal is OFF during pre-excitation with the LX signal ON.)
Output
signal
Start signal
OFF (inverter
stopped)
Start signal
ON (inverter
stopped)
Start signal
ON
(inverter
running)
During DC
injection
brake
operation
Inverter output
shutoff
Automatic restart after
instantaneous power failure
During coasting
Inverter
running
after
restart
Start
signal ON
Start
signal OFF
Start
signal ON
Start
signal OFF
ON
ON
ON
ON
OFF
ON
ON
RY2
OFF
OFF
OFF
OFF
OFF
OFF
OFF
RUN
OFF
OFF
ON
OFF
OFF
OFF
ON
RUN2
OFF
OFF
ON
OFF
OFF
OFF
ON
RUN3
OFF
ON
ON
ON
ON
OFF
ON
OFF
ON
Power
supply
Output frequency
STF
RH
RY
RUN3
Reset
processing
Time
ON
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
RUN
(RUN2)
DC injection brake
operation point
DC injection
brake
operation
Pr. 13
Summary of Contents for FR-E800
Page 17: ...16 1 Introduction 1 3 Related manuals MEMO ...
Page 51: ...50 2 Basic Operation 2 8 I O terminal function assignment MEMO ...
Page 89: ...88 3 Parameters 3 4 Parameter list by function group number MEMO ...
Page 135: ...134 5 Speed Control 5 9 Troubleshooting in the speed control MEMO ...
Page 153: ...152 6 Torque Control 6 7 Troubleshooting in torque control MEMO ...
Page 195: ...194 8 E Environment Setting Parameters 8 18 Current average value monitor signal MEMO ...
Page 237: ...236 10 D Operation Command and Frequency Command 10 6 Operation by multi speed setting MEMO ...
Page 339: ...338 13 T Multi Function Input Terminal Parameters 13 9 Start signal operation selection MEMO ...
Page 455: ...454 16 G Control Parameters 16 13 Speed smoothing control MEMO ...