168
8. (E) Environment Setting Parameters
8.6 Automatic frequency setting / key lock operation selection
Disabling the setting dial and keys on the operation panel (by holding
down the MODE key for 2 seconds)
• Operation using the setting dial and keys of the operation panel can be disabled to prevent parameter changes,
unexpected starts or frequency changes.
• Set
Pr.161
to "10 or 11" and then press the MODE key for 2 seconds to disable setting dial or key operations.
• When the setting dial and key operation are disabled, "HOLD" appears on the operation panel. If setting dial or key
operation is attempted while dial and key operations are disabled, "HOLD" appears. (After no setting dial or key operation
for 2 seconds, the display returns to the monitoring screen.)
• To enable the setting dial and key operation again, press the MODE key for 2 seconds.
NOTE
• Even if setting dial and key operations are disabled, the monitor indicator and STOP/RESET key are enabled.
• The PU stop warning cannot be reset by using keys while the key lock function is enabled.
Parameters referred to
Pr.1 Maximum frequency
Summary of Contents for FR-E800
Page 17: ...16 1 Introduction 1 3 Related manuals MEMO ...
Page 51: ...50 2 Basic Operation 2 8 I O terminal function assignment MEMO ...
Page 89: ...88 3 Parameters 3 4 Parameter list by function group number MEMO ...
Page 135: ...134 5 Speed Control 5 9 Troubleshooting in the speed control MEMO ...
Page 153: ...152 6 Torque Control 6 7 Troubleshooting in torque control MEMO ...
Page 195: ...194 8 E Environment Setting Parameters 8 18 Current average value monitor signal MEMO ...
Page 237: ...236 10 D Operation Command and Frequency Command 10 6 Operation by multi speed setting MEMO ...
Page 339: ...338 13 T Multi Function Input Terminal Parameters 13 9 Start signal operation selection MEMO ...
Page 455: ...454 16 G Control Parameters 16 13 Speed smoothing control MEMO ...