56
3. Parameters
3.2 Parameter list (by parameter number)
—
65
H300
Retry selection
0 to 5
1
0
—
66
H611
Stall prevention operation
reduction starting frequency
0 to 590 Hz
0.01 Hz
60 Hz 50 Hz
Ret
ry
67
H301
Number of retries at fault
occurrence
0 to 10, 101 to 110
1
0
68
H302
Retry waiting time
0.1 to 600 s
0.1 s
1 s
69
H303
Retry count display erase
0
1
0
—
70
G107
Special regenerative brake
duty
0% to 100%
0.1%
0%
—
71
C100
Applied motor
[200/400 V class]
0, 3, 5, 6, 10, 13, 15,
16, 20, 23, 30, 33, 40,
43, 50, 53, 70, 73,
1800, 1803, 8090,
8093, 9090, 9093
[575 V class]
0, 3, 5, 6, 10, 13, 15,
16, 30, 33, 8090, 8093,
9090, 9093
1
0
,
,
—
72
E600
PWM frequency selection
0 to 15
1
1
—
73
T000
Analog input selection
0, 1, 6, 10, 11, 16
1
1
—
74
T002
Input filter time constant
0 to 8
1
1
—
75
—
Reset selection/
disconnected PU detection/
PU stop selection
[E800(-E)]
0 to 3, 14 to 17
[E800-SCE]
0 to 3, 14 to 17, 10000
to 10003, 10014 to
10017
1
[E800(-E)]
14
[E800-SCE]
10014
E100
Reset selection
0, 1
0
E101
Disconnected PU detection
E102
PU stop selection
1
E107
Reset limit
0, 10 [E800-SCE]
[E800(-E)]
0
[E800-SCE]
10
—
77
E400
Parameter write selection
0 to 2
1
0
—
78
D020
Reverse rotation prevention
selection
0 to 2
1
0
—
79
D000
Operation mode
selection
0 to 4, 6, 7
1
0
,
Function
Pr.
Pr.
group
Name
Setting range
Minimum
setting
increments
Initial
value
*1
Refer
to page
Customer
setting
Gr.1
Gr.2
Simple
Simple
Simple
Summary of Contents for FR-E800
Page 17: ...16 1 Introduction 1 3 Related manuals MEMO ...
Page 51: ...50 2 Basic Operation 2 8 I O terminal function assignment MEMO ...
Page 89: ...88 3 Parameters 3 4 Parameter list by function group number MEMO ...
Page 135: ...134 5 Speed Control 5 9 Troubleshooting in the speed control MEMO ...
Page 153: ...152 6 Torque Control 6 7 Troubleshooting in torque control MEMO ...
Page 195: ...194 8 E Environment Setting Parameters 8 18 Current average value monitor signal MEMO ...
Page 237: ...236 10 D Operation Command and Frequency Command 10 6 Operation by multi speed setting MEMO ...
Page 339: ...338 13 T Multi Function Input Terminal Parameters 13 9 Start signal operation selection MEMO ...
Page 455: ...454 16 G Control Parameters 16 13 Speed smoothing control MEMO ...