231
10. (D) Operation Command and Frequency Command
10.4 Reverse rotation prevention selection
10.4
Reverse rotation prevention selection
This function can prevent reverse rotation fault resulting from the incorrect input of the start signal.
• Set this parameter to limit the motor rotation to only one direction.
• This parameter is valid for all of the RUN key of the operation panel, the start signals (STF, STR signals) via external
terminals, and the forward and reverse rotation commands through communication.
Pr.
Name
Initial value
Setting range
Description
78
D020
Reverse rotation
prevention selection
0
0
Both forward and reverse rotations allowed
1
Reverse rotation disabled
2
Forward rotation disabled