17. Checking and Clearing of Settings
17.2 List of parameters changed from the initial values
17.2
List of parameters changed from the initial values
Parameters changed from their initial values can be displayed.
Operating procedure
1.
Turning ON the power of the inverter
The operation panel is in the monitor mode.
2.
Selecting the parameter setting mode
Press the MODE key to choose the parameter setting mode. (The parameter number read previously appears.)
3.
Selecting the parameter
Turn the setting dial or press the UP/DOWN key until "Pr.CH" (Initial value change list) appears, and set the SET key.
"P.---" blinks and then remains displayed.
4.
Checking the Initial value change list
Turn the setting dial or press the UP/DOWN key after blinking stops to display the parameter numbers that have
been changed from their initial values in order.
●
When the SET key is pressed with a changed parameter displayed, the parameter settings can be changed as
they are. (Parameter numbers are no longer displayed in the list when they are returned to their initial values.)
Turn the setting dial or press the UP/DOWN key to display another changed parameter.
●
The indication returns to "P.---" when the last changed parameter is displayed.
NOTE
• Calibration parameters
(C0 (Pr.900) to C7 (Pr.905), C38 (Pr.932) to C45 (Pr.935))
are not displayed even when these are
changed from the initial settings.
• Only the simple mode parameters are displayed when the simple mode is set (
Pr.160
="9999").
• Only user groups are displayed when user groups are set (
Pr.160
= "1").
•
Pr.160
is displayed independently of whether the setting value is changed or not.
Summary of Contents for FR-E800
Page 17: ...16 1 Introduction 1 3 Related manuals MEMO ...
Page 51: ...50 2 Basic Operation 2 8 I O terminal function assignment MEMO ...
Page 89: ...88 3 Parameters 3 4 Parameter list by function group number MEMO ...
Page 135: ...134 5 Speed Control 5 9 Troubleshooting in the speed control MEMO ...
Page 153: ...152 6 Torque Control 6 7 Troubleshooting in torque control MEMO ...
Page 195: ...194 8 E Environment Setting Parameters 8 18 Current average value monitor signal MEMO ...
Page 237: ...236 10 D Operation Command and Frequency Command 10 6 Operation by multi speed setting MEMO ...
Page 339: ...338 13 T Multi Function Input Terminal Parameters 13 9 Start signal operation selection MEMO ...
Page 455: ...454 16 G Control Parameters 16 13 Speed smoothing control MEMO ...