342
14. (C) Motor Constant Parameters
14.1 Applied motor
NOTE
• Regardless of the
Pr.71 (Pr.450)
setting, offline auto tuning can be performed according to
Pr.96 (Pr.463) Auto tuning
setting/status
. (Refer to
for offline auto tuning.)
Motor settings (575 V class)
• Refer to the following list and set the parameters according to the applied motor.
NOTE
• Regardless of the
Pr.71 (Pr.450)
setting, offline auto tuning can be performed according to
Pr.96 (Pr.463) Auto tuning
setting/status
. (Refer to
for offline auto tuning.)
Using two types of motors (RT signal, Pr.450)
• When using two types of motors with one inverter, set
Pr.450 Second applied motor
.
• The setting value "9999" (initial value) disables the second motor.
• If
Pr.450
≠
9999, the following parameters will be enabled by turning ON the Second function selection (RT) signal.
Pr.71
Pr.450
Motor
Motor constant value range when performing
offline auto tuning (increment)
Electronic thermal O/L
relay function
Standard
Constant-
torque
0 (
Pr.71
initial value) Standard motor
Pr.82 (Pr.455), Pr.859 (Pr.860)
• 0 to 500 A, 9999 (0.01 A)
Pr.90 (Pr.458), Pr.91 (Pr.459)
• 0 to 50
Ω
, 9999 (0.001
Ω
)
Pr.92 (Pr.460), Pr.93 (Pr.461) (Induction motor)
• 0 to 6000 mH, 9999 (0.1 mH)
Pr.92 (Pr.460), Pr.93 (Pr.461) (PM motor)
• 0 to 650 mH, 9999 (0.01 mH)
Pr.94 (Pr.462)
• 0% to 100%, 9999 (0.1%)
Pr.706 (Pr.738)
• 0 to 5000 mV (rad/s), 9999 (0.1 mV/(rad/s))
○
10
Constant-torque motor
○
30
Vector control dedicated motor
○
8090
IPM motor
○
9090
SPM motor
○
3
Standard motor
Pr.82 (Pr.455), Pr.859 (Pr.860), Pr.90 (Pr.458),
Pr.91 (Pr.459), Pr.92 (Pr.460), Pr.93 (Pr.461),
Pr.94 (Pr.462), Pr.706 (Pr.738)
• Internal data value 0 to 65534, 9999 (1)
○
13
Constant-torque motor
○
33
Vector control dedicated motor
○
8093
IPM motor
○
9093
SPM motor
○
5
Standard motor
Wye
connection
Pr.82 (Pr.455) and Pr.859 (Pr.860)
• 0 to 500 A, 9999 (0.01 A)
Pr.90 (Pr.458), Pr.91 (Pr.459),
Pr.92 (Pr.460) and Pr.93 (Pr.461)
• 0 to 50
Ω
, 9999 (0.001
Ω
)
Pr.92 (Pr.460), Pr.93 (Pr.461)
• 0 to 50
Ω
, 9999 (0.001
Ω
)
Pr.94 (Pr.462)
• 0 to 500
Ω
, 9999 (0.01
Ω
)
○
15
Constant-torque motor
○
6
Standard motor
Delta
connection
○
16
Constant-torque motor
○
—
9999
(initial
value)
No second applied motor
Summary of Contents for FR-E800
Page 17: ...16 1 Introduction 1 3 Related manuals MEMO ...
Page 51: ...50 2 Basic Operation 2 8 I O terminal function assignment MEMO ...
Page 89: ...88 3 Parameters 3 4 Parameter list by function group number MEMO ...
Page 135: ...134 5 Speed Control 5 9 Troubleshooting in the speed control MEMO ...
Page 153: ...152 6 Torque Control 6 7 Troubleshooting in torque control MEMO ...
Page 195: ...194 8 E Environment Setting Parameters 8 18 Current average value monitor signal MEMO ...
Page 237: ...236 10 D Operation Command and Frequency Command 10 6 Operation by multi speed setting MEMO ...
Page 339: ...338 13 T Multi Function Input Terminal Parameters 13 9 Start signal operation selection MEMO ...
Page 455: ...454 16 G Control Parameters 16 13 Speed smoothing control MEMO ...