10. (D) Operation Command and Frequency Command
10.2 Startup of the inverter in Network operation mode at power-ON
10.2
Startup of the inverter in Network operation mode
at power-ON
When power is switched ON or when power comes back ON after an instantaneous power failure, the inverter can be started
up in the Network operation mode.
After the inverter starts up in the Network operation mode, parameter writing and operation can be commanded from programs.
Set this mode when performing communication operation using the RS-485 terminals or a communication option.
Selecting the operation mode for power-ON (Pr.340)
• Depending on the
Pr.79
and
Pr.340
settings, the operation mode at power-ON (reset) changes as described below.
*1
The operation mode cannot be directly changed between the PU operation mode and Network operation mode.
*2
Switching between the PU and NET operation modes is available with the PU/EXT key on the operation panel and the X65 signal.
Parameters referred to
Pr.57 Restart coasting time
,
Pr.79 Operation mode selection
Pr.
Name
Initial value
Setting range
Description
79
D000
Operation mode selection
0
0 to 4, 6, 7
Selects the operation mode.
(Refer to
.)
340
D001
Communication startup mode
selection
[E800]
0
[E800-(SC)E]
10
0
The inverter starts up in an operation mode selected in
Pr.79
.
1
The inverter starts up in the Network operation mode.
10
The inverter starts up in the Network operation mode.
The operation mode can be changed between the PU
operation mode and Network operation mode from the
operation panel.
Pr.340
setting
Pr.79
setting
Operation mode at power-ON, at
power restoration, or after a reset
Operation mode switching
0
0 (initial
value)
External operation mode
Switching among the External, PU, and NET operation modes is
enabled
1
PU operation mode
Fixed at PU operation mode.
2
External operation mode
Switching between the External and NET operation modes is enabled.
Switching to PU operation mode is disabled.
3, 4
External/PU combined operation mode
Operation mode switching is disabled.
6
External operation mode
Switching among the External, PU, and NET operation mode is
enabled during operation.
7
X12 (MRS) signal ON: External
operation mode
Switching among the External, PU, and NET operation modes is
enabled
X12 (MRS) signal OFF: External
operation mode
Fixed at External operation mode (forcibly switched to External
operation mode).
1
0
NET operation mode
Same as
Pr.340
= "0".
1
PU operation mode
2
NET operation mode
3, 4
External/PU combined operation mode
6
NET operation mode
7
X12 (MRS) signal ON: NET operation
mode
X12 (MRS) signal OFF: External
operation mode
10
0
NET operation mode
Switching between the PU and NET operation mode is enabled.
1
PU operation mode
Same as
Pr.340
= "0".
2
NET operation mode
Fixed at NET operation mode.
3, 4
External/PU combined operation mode
Same as
Pr.340
= "0".
6
NET operation mode
Switching between the PU and NET operation mode is enabled during
operation.
7
External operation mode
Same as
Pr.340
= "0".
Summary of Contents for FR-E800
Page 17: ...16 1 Introduction 1 3 Related manuals MEMO ...
Page 51: ...50 2 Basic Operation 2 8 I O terminal function assignment MEMO ...
Page 89: ...88 3 Parameters 3 4 Parameter list by function group number MEMO ...
Page 135: ...134 5 Speed Control 5 9 Troubleshooting in the speed control MEMO ...
Page 153: ...152 6 Torque Control 6 7 Troubleshooting in torque control MEMO ...
Page 195: ...194 8 E Environment Setting Parameters 8 18 Current average value monitor signal MEMO ...
Page 237: ...236 10 D Operation Command and Frequency Command 10 6 Operation by multi speed setting MEMO ...
Page 339: ...338 13 T Multi Function Input Terminal Parameters 13 9 Start signal operation selection MEMO ...
Page 455: ...454 16 G Control Parameters 16 13 Speed smoothing control MEMO ...