If you have a Kaleido-X (4RU) without a KXA-GPI-GEN card, then you will find the fan and power supply
statuses listed with the master output card’s information:
Obtaining EDID Data From Display Screens When Using the DXF-100 Interface
The DXF-100 is a transmitter/receiver combination that allows a digital flat panel display to be located up
to 1,000 meters (3,300 feet) away from the signal source. The transmitter and receiver are interconnected
by a single multimode optical fiber, and connect to the source and display using DVI connectors.
The DXF-100 must be configured for its target display,
before
it is connected to the Kaleido-X, otherwise
the Extended display identification data (EDID) information listed in XAdmin’s
Status and Options
page
for the corresponding output card will not reflect the actual values for the target display. XAdmin would
not be reporting the actual timing data from the display, but default values corresponding to the
maximum resolution supported by the DXF-100, i.e. 1920×1200. The DXF-100 interface is unidirectional
from the transmitter (Kaleido-X) to the receiver (display). For XAdmin to show timing data from the
display, the EDID information needs to be transmitted in the reverse direction: from the display to the
Kaleido-X.
Temperatures
PSU statuses
Fan statuses
Summary of Contents for Kaleido-X (4RU)
Page 4: ...iv ...
Page 54: ...44 GettingStarted 1 ...
Page 58: ...48 New Features 2 ...
Page 88: ...78 Operation of the Monitor Wall 3 ...
Page 120: ...110 Calibratingthe Kaleido X 5 CalibratingMetadata Holding Time 134 CalibratingGPI Lines 136 ...
Page 160: ...150 Configuring Alarms 6 ...
Page 168: ...158 Creating Channels 7 ...
Page 252: ...242 Creating Layouts 9 ...
Page 264: ...254 Creating Actions 10 ...
Page 358: ...348 Third Party Devices 13 ...
Page 360: ......
Page 362: ...352 Using the Serial to TCP IP Dispatcher 15 ...
Page 380: ...370 Administration andServicing 16 ...
Page 382: ......
Page 388: ...378 Index Zooming59 ...