D-74
(2)
Adjustment of Turnover Roller Retraction Solenoid
Requirement
The gap between the E-ring of the plunger and the Retraction Solenoid should be 3 ± 0.2
mm when the Retraction Solenoid OFF.
Adjustment Procedure
3. Move the Retraction Solenoid so that the gap between the E-ring of the plunger and the
Solenoid is 3 ± 0.2 mm when the Retraction Solenoid OFF.
4. After adjustment is completed, tighten the two Retraction Solenoid mounting screws.
1. Slide out the Fusing Unit.
2. Loosen two screws by which the Retraction Sole-
noid is mounted.
4002D210AC
4002D012AA
3 ± 0.2 mm