D-72
3-5.
SOLENOID POSITION ADJUSTMENT
(1)
Adjustment of Manual Feed Paper Pick-Up Solenoid
Requirement
The Paper Stoppers should be fixed perpendicularly when the Pick-Up Solenoid is ON.
Adjustment Procedure
1. Remove the Right Cover.
2. Remove five screws and the Manual Feed Paper
Pick-Up Solenoid mounting bracket Assy.
4002D090AB
3. Remove two screws and the bracket.
4002D206AB
4. Set the Pick-Up Solenoid to ON.
Reference
Since a keeper solenoid is used as the Pick-Up Sole-
noid, the set condition is kept when the Pick-Up Sole-
noid is on.
4002D207AA
Summary of Contents for DI450