S-44
Touch Panel
Display
Setting (The default is
).
Leading Edge
Erase
Select whether to enable or disable the leading edge erase.
Trailing Edge
Erase
Select whether to enable or disable the trailing edge erase.
Loop Adjustment
Set the length of the loop to be formed in paper before the Synchro-
nizing Rollers.
VG Adjust
Vary the Vg voltage to set the desired image density.
Zoom (CD)
Set the correction value for the zoom ratio in the CD direction on the
IR side.
Zoom (FD)/Manual Set the correction value for the zoom ratio in the FD direction on the
IR side.
Scale (FD)
Set the correction value for the start-of-scan position of the original in
the FD direction with respect to the Original Width Scale position.
Scale (CD)
Set the correction value for the start-of-scan position of the original in
the CD direction with respect to the Original Length Scale position.
Zoom (FD) EDH
Set the correction value for the zoom ratio in the FD direction when
the EDH is used.
Feed (2)
Set the correction value for the original scanning position for the sec-
ond page of a 2-sided original when the EDH is used.
Highlighted
0 to 5 (
)
3 mm
0 to 5 (
)
3 mm
Setting
-3 ...................................
..................................+3
Description Smaller
Greater
0
Setting
-4 ...................................
..................................+4
Description
Lighter
Darker
0
0.990 to 1.010 (
)
1.000
0.990 to 1.010 (
)
1.000
-4.0 to +4.0 (
)
0.0 mm
-10.0 to +10.0 (
)
0.0 mm
0.980 to 1.020 (
)
1.000
-5.0 to +5.0 (
)
0.0 mm
Summary of Contents for DI450
Page 13: ......
Page 14: ...DIS REASSEMBLY ADJUSTMENT ...
Page 15: ......
Page 138: ...SWITCHES ON PWBs TECH REP SETTINGS ...
Page 139: ......
Page 141: ......
Page 161: ...S 20 Punch Loop Adjust Tech Rep Mode Sensors Port Signals Finisher I O Check ...
Page 187: ......
Page 188: ...TROUBLESHOOTING 13430 ...
Page 189: ......