D-87
(7)
Lead Edge Erase
Requirement
This adjustment must be made after the PH Unit has been replaced and following Registra-
tion (CD/FD).
Adjustment Procedure
1. Call the Adjust mode to the screen.
2. Touch [Printer].
3. Touch [Lead Edge Erase].
4. Press the Start Key to let the copier produce a test pattern.
5. Check to see if width A on the test pattern is up to the specifications. If it is outside the
specified range, perform the following adjustment steps.
Specification
Adjust Mode
Setting Range
3.0 ± 1.0 mm
Lead Edge Erase
0 to 5
Width A on the test pattern output should fall within the
following range.
NOTE
The measurement shall be taken at the center on the
leading edge of the paper.
1155D156AB